Nowhere to Report: Vulnerability Disclosure Channels at US Hospitals, Medical Device Makers, and Health IT Developers. A Cross-sectional Web Measurement

Objective To measure whether US hospitals, medical device manufacturers and certified electronic health record (EHR) developers publish any channel for reporting a security vulnerability. Materials and Methods A cross-sectional crawl in November 2026 visited domains on five public lists: hospitals listing a website (2,652), companies on FDA's list of AI-enabled medical devices (device makers, 525), vendors named in CISA medical advisories (advisory vendors, 75), developers of ONC-certified API technology (EHR developers, 200) and federal health agencies (the federal control, 124). Channels were security.txt, a disclosure policy page (judged by language models), a platform listing or CVE Numbering Authority status. Results Of these, 1,721 hospital domains could be measured (615 unreachable), as could 436 device-maker, 67 advisory-vendor, 181 EHR-developer and 101 federal-control domains. A channel was found at 87.6% (95% CI, 79.0%-93.7%) of federal-control, 8.2% (6.9%-9.6%) of hospital, 20.5% (16.7%-24.8%) of device-maker, 41.0% (28.6%-54.3%) of advisory-vendor and 7.9% (4.3%-13.2%) of EHR-developer domains. One health system's file served 95 of 132 hospital domains with security.txt; per distinct final site (post hoc), 3.1% (2.2%-4.1%) had one. On the same domains, 91.0% served a valid cms-hpt.txt, required by a price-transparency rule, and 7.9% security.txt. Discussion Channels were common where a directive requires them and rarer elsewhere, an association, not an effect of regulation. Per-domain counts overstate how many hospital organizations publish one. Conclusion Most organizations on these lists published no vulnerability reporting channel; most federal-control domains did. Among hospitals, channels came mostly from a few health systems. Whether such reports are answered remains untested.

Authors

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11806113/v1
Primary Topic
Information and Cyber Security
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Nowhere to Report: Vulnerability Disclosure Channels at US Hospitals, Medical Device Makers, and Health IT Developers. A Cross-sectional Web Measurement

Christopher Jagdeo
Research Square
Information and Cyber Security
preprint

Nowhere to Report: Vulnerability Disclosure Channels at US Hospitals, Medical Device Makers, and Health IT Developers. A Cross-sectional Web Measurement

Christopher Jagdeo
preprint en

Abstract

Objective To measure whether US hospitals, medical device manufacturers and certified electronic health record (EHR) developers publish any channel for reporting a security vulnerability. Materials and Methods A cross-sectional crawl in November 2026 visited domains on five public lists: hospitals listing a website (2,652), companies on FDA's list of AI-enabled medical devices (device makers, 525), vendors named in CISA medical advisories (advisory vendors, 75), developers of ONC-certified API technology (EHR developers, 200) and federal health agencies (the federal control, 124). Channels were security.txt, a disclosure policy page (judged by language models), a platform listing or CVE Numbering Authority status. Results Of these, 1,721 hospital domains could be measured (615 unreachable), as could 436 device-maker, 67 advisory-vendor, 181 EHR-developer and 101 federal-control domains. A channel was found at 87.6% (95% CI, 79.0%-93.7%) of federal-control, 8.2% (6.9%-9.6%) of hospital, 20.5% (16.7%-24.8%) of device-maker, 41.0% (28.6%-54.3%) of advisory-vendor and 7.9% (4.3%-13.2%) of EHR-developer domains. One health system's file served 95 of 132 hospital domains with security.txt; per distinct final site (post hoc), 3.1% (2.2%-4.1%) had one. On the same domains, 91.0% served a valid cms-hpt.txt, required by a price-transparency rule, and 7.9% security.txt. Discussion Channels were common where a directive requires them and rarer elsewhere, an association, not an effect of regulation. Per-domain counts overstate how many hospital organizations publish one. Conclusion Most organizations on these lists published no vulnerability reporting channel; most federal-control domains did. Among hospitals, channels came mostly from a few health systems. Whether such reports are answered remains untested.

Research Square
Information and Cyber Security
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon