Interrater agreement of seizure onset and spread in scalp EEG

Objective. Faster seizure spread on intracranial EEG has been linked to worse surgical outcome. If contralateral spread on scalp EEG carried similar prognostic information, it could identify poor resection candidates before intracranial monitoring and direct them toward neuromodulation sooner. Testing this first requires that experts reliably annotate spread on scalp EEG. The interrater agreement for seizure spread detection on scalp EEG is unknown; prior scalp EEG reliability studies have focused mainly on seizure detection. We quantified expert agreement on the laterality, channels, and timing of seizure onset and contralateral spread. Methods. We retrospectively analyzed 79 seizures from 48 patients undergoing presurgical evaluation at a single center. Three board certified epileptologists independently marked the time and channels of onset and contralateral spread for each seizure. We measured agreement on onset laterality and spread presence with Gwet k, channels with Cohen k, and timing with the median absolute deviation (MAD). Interrater and majority vote consensus agreement were estimated with patient-clustered CIs. Results. Onset laterality showed substantial interrater agreement (Gwet k = 0.73, 95% CI 0.62 to 0.83); most disagreement involved bilateral onsets. Contralateral spread agreement was comparable (0.63, 0.48 to 0.76). Channel level agreement was higher for onset (inter rater Cohen k = 0.57) than for spread (0.38). Onset timing was highly consistent (median MAD 0.40 s); spread timing agreement was also high (1.99 s), but less so than onset timing (sign rank p < 0.001). Agreement did not differ across annotators or between temporal and non-temporal epilepsy. Significance. Epileptologists generally agree on onset laterality and whether and when seizures spread contralaterally, although spread channels are identified less reliably. These findings support the feasibility of measuring scalp EEG spread as a candidate noninvasive marker of seizure network extent. The public annotated dataset provides a multi-expert reference standard for developing automated spread detection algorithms.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-23
DOI
https://doi.org/10.64898/2026.11.20.26366721
Primary Topic
Epilepsy research and treatment
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Interrater agreement of seizure onset and spread in scalp EEG

Odile Feys, Christina M. Boada, Russell Taki Shinohara, Erin C. Conrad et al.
medRxiv
Epilepsy research and treatment
preprint

Interrater agreement of seizure onset and spread in scalp EEG

Odile Feys, Christina M. Boada, Russell Taki Shinohara, Erin C. Conrad, Madeline Stecy, Kathryn A. Davis, William K.S. Ojemann, Carlos A. Aguila, Juri Kim, Daniel Zhou, Julian Gal
preprint en

Abstract

Objective. Faster seizure spread on intracranial EEG has been linked to worse surgical outcome. If contralateral spread on scalp EEG carried similar prognostic information, it could identify poor resection candidates before intracranial monitoring and direct them toward neuromodulation sooner. Testing this first requires that experts reliably annotate spread on scalp EEG. The interrater agreement for seizure spread detection on scalp EEG is unknown; prior scalp EEG reliability studies have focused mainly on seizure detection. We quantified expert agreement on the laterality, channels, and timing of seizure onset and contralateral spread. Methods. We retrospectively analyzed 79 seizures from 48 patients undergoing presurgical evaluation at a single center. Three board certified epileptologists independently marked the time and channels of onset and contralateral spread for each seizure. We measured agreement on onset laterality and spread presence with Gwet k, channels with Cohen k, and timing with the median absolute deviation (MAD). Interrater and majority vote consensus agreement were estimated with patient-clustered CIs. Results. Onset laterality showed substantial interrater agreement (Gwet k = 0.73, 95% CI 0.62 to 0.83); most disagreement involved bilateral onsets. Contralateral spread agreement was comparable (0.63, 0.48 to 0.76). Channel level agreement was higher for onset (inter rater Cohen k = 0.57) than for spread (0.38). Onset timing was highly consistent (median MAD 0.40 s); spread timing agreement was also high (1.99 s), but less so than onset timing (sign rank p < 0.001). Agreement did not differ across annotators or between temporal and non-temporal epilepsy. Significance. Epileptologists generally agree on onset laterality and whether and when seizures spread contralaterally, although spread channels are identified less reliably. These findings support the feasibility of measuring scalp EEG spread as a candidate noninvasive marker of seizure network extent. The public annotated dataset provides a multi-expert reference standard for developing automated spread detection algorithms.

medRxiv
University of Washington (US), University of Pennsylvania (US)
Epilepsy research and treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon