Baseline Haematological Profile and A Biomarker-Based Framework for Monitoring Insecticide Stress in Catla Catla (Hamilton, 1822) From Yeldari Reservoir, Maharashtra

Background: Agricultural insecticides reach freshwater reservoirs through runoff, drainage, leaching and accidental discharge, and fish are exposed continuously through gills, skin and diet. Catla catla, an Indian major carp of high economic and ecological value, is a suitable sentinel species. Blood parameters are sensitive indicators of health and environmental stress, but they can be used for monitoring only when species-specific baselines exist and when the measurement method is validated. Objective: To (i) review the physiological, haematological, biochemical, oxidative and histopathological responses of K. catla to insecticides; (ii) establish a baseline haematological profile of catla using an automated analyser; and (iii) integrate this baseline into a six-module biomarker-based monitoring system for Yeldari Reservoir. Methods: Whole blood from six catla specimens was analysed in whole-blood CBC+DIFF mode on a five-part-differential analyser on 12 November 2025 and summarised as mean ± SD. Results: Mean RBC was 1.83 ± 0.02 × 10⁶/µL, haemoglobin 12.53 ± 0.15 g/dL, haematocrit 33.48 ± 0.40 %, MCV 183.3 ± 1.7 fL, MCH 68.6 ± 1.3 pg and MCHC 37.4 ± 0.7 g/dL. The instrument reported WBC of 68.49 ± 3.37 × 10³/µL with 97.3 % lymphocytes, and every sample carried the flags "abnormal/atypical lymphocytes", "leucocytosis", "lymphocytosis" and "macrocytosis". Conclusion: Erythrocyte variables were highly reproducible and can serve as a preliminary baseline for the haematological module of the monitoring system. The leukocyte output is very probably inflated by nucleated erythrocytes and thrombocytes counted as lymphocytes, so it must not be interpreted as true leucocytosis; manual counts on stained smears are required. The integrated system links catchment pesticide-use surveys, seasonal field monitoring, laboratory bioassays, a multi-biomarker panel, data integration (Integrated Biomarker Response and risk quotient) and decision support.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-23
DOI
https://doi.org/10.5281/zenodo.24465647
Primary Topic
Environmental Toxicology and Ecotoxicology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Baseline Haematological Profile and A Biomarker-Based Framework for Monitoring Insecticide Stress in Catla Catla (Hamilton, 1822) From Yeldari Reservoir, Maharashtra

Niwrati Govindrao Popatwar, Pooja Dinkarappa Tarte
Zenodo (CERN European Organization for Nuclear Research)
Environmental Toxicology and Ecotoxicology
article

Baseline Haematological Profile and A Biomarker-Based Framework for Monitoring Insecticide Stress in Catla Catla (Hamilton, 1822) From Yeldari Reservoir, Maharashtra

Niwrati Govindrao Popatwar, Pooja Dinkarappa Tarte
article en

Abstract

Background: Agricultural insecticides reach freshwater reservoirs through runoff, drainage, leaching and accidental discharge, and fish are exposed continuously through gills, skin and diet. Catla catla, an Indian major carp of high economic and ecological value, is a suitable sentinel species. Blood parameters are sensitive indicators of health and environmental stress, but they can be used for monitoring only when species-specific baselines exist and when the measurement method is validated. Objective: To (i) review the physiological, haematological, biochemical, oxidative and histopathological responses of K. catla to insecticides; (ii) establish a baseline haematological profile of catla using an automated analyser; and (iii) integrate this baseline into a six-module biomarker-based monitoring system for Yeldari Reservoir. Methods: Whole blood from six catla specimens was analysed in whole-blood CBC+DIFF mode on a five-part-differential analyser on 12 November 2025 and summarised as mean ± SD. Results: Mean RBC was 1.83 ± 0.02 × 10⁶/µL, haemoglobin 12.53 ± 0.15 g/dL, haematocrit 33.48 ± 0.40 %, MCV 183.3 ± 1.7 fL, MCH 68.6 ± 1.3 pg and MCHC 37.4 ± 0.7 g/dL. The instrument reported WBC of 68.49 ± 3.37 × 10³/µL with 97.3 % lymphocytes, and every sample carried the flags "abnormal/atypical lymphocytes", "leucocytosis", "lymphocytosis" and "macrocytosis". Conclusion: Erythrocyte variables were highly reproducible and can serve as a preliminary baseline for the haematological module of the monitoring system. The leukocyte output is very probably inflated by nucleated erythrocytes and thrombocytes counted as lymphocytes, so it must not be interpreted as true leucocytosis; manual counts on stained smears are required. The integrated system links catchment pesticide-use surveys, seasonal field monitoring, laboratory bioassays, a multi-biomarker panel, data integration (Integrated Biomarker Response and risk quotient) and decision support.

Zenodo (CERN European Organization for Nuclear Research)
Environmental Toxicology and Ecotoxicology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Baseline Haematological Profile and A Biomarker-Based Framework for Monitoring Insecticide Stress in Catla Catla (Hamilton, 1822) From Yeldari Reservoir, Maharashtra — Niwrati Govindrao Popatwar, Pooja Dinkarappa Tarte · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS