Pointwise and mean-square conditions for residual correction of state estimators: a trust-region UKF–ANFIS framework for cascaded SOC and SOH estimation in VRLA gel batteries

Accurate state-of-charge (SOC) and state-of-health (SOH) estimation is essential for stationary valve-regulated lead-acid (VRLA) gel batteries. Residual-correction hybrids are widely used, but a non-zero learned correction can increase rather than reduce a Kalman-filter error. We derive a necessary and sufficient pointwise condition for non-degradation, the mean-square condition for a shrinkage-scaled correction, and a closed-form expression for the optimal attainable reduction in terms of the uncentred alignment coefficient between the learned correction and the baseline error. Because the true error is unavailable online, the theorem is not itself an implementable guarantee. We therefore introduce covariance-based trust-region projection and an innovation gate as observable risk controls and prove a conditional mean-square boundedness result. The construction is instantiated by an ANFIS residual model applied to a parameter-augmented UKF. Corrected SOC, together with four explicitly defined health indices, feeds a second ANFIS stage for SOH. Evaluation uses a structurally distinct 2RC-hysteresis data generator, a 24-month ageing horizon, disjoint train/validation/test profiles, and paired repeated-Monte-Carlo analysis. Across eleven estimators (the proposed method plus ten baselines, including a protocol-matched implementation of the published EKF-ANN architecture of Dao et al.), the proposed SOC estimator obtained the lowest RMSE, 0.942 %, versus 1.314 % for its UKF baseline and 1.022 % for the linear-correction ablation. The test-set alignment coefficient was 0.716, corresponding to an optimal attainable RMSE reduction of 30.2 %; the validation-scaled correction achieved 28.3 %. Under a sign-reversed stress test, strict projection and gating reduced the damage relative to an ungated correction but did not preserve baseline RMSE, confirming that the online controls are risk-limiting surrogates rather than a pointwise guarantee. The SOH ANFIS stage was outperformed by a linear corrector, which is reported as a limitation.

Authors

Publication Details

Journal
Mathematical Models in Engineering
Published
2026-11-23
DOI
https://doi.org/10.21595/mme.2026.26925
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Pointwise and mean-square conditions for residual correction of state estimators: a trust-region UKF–ANFIS framework for cascaded SOC and SOH estimation in VRLA gel batteries

Каримберди Каршиев, Igor Kolesnikov, Otabek Boltaev
Mathematical Models in Engineering
Battery Modeling and Management
article

Pointwise and mean-square conditions for residual correction of state estimators: a trust-region UKF–ANFIS framework for cascaded SOC and SOH estimation in VRLA gel batteries

Каримберди Каршиев, Igor Kolesnikov, Otabek Boltaev
article en

Abstract

Accurate state-of-charge (SOC) and state-of-health (SOH) estimation is essential for stationary valve-regulated lead-acid (VRLA) gel batteries. Residual-correction hybrids are widely used, but a non-zero learned correction can increase rather than reduce a Kalman-filter error. We derive a necessary and sufficient pointwise condition for non-degradation, the mean-square condition for a shrinkage-scaled correction, and a closed-form expression for the optimal attainable reduction in terms of the uncentred alignment coefficient between the learned correction and the baseline error. Because the true error is unavailable online, the theorem is not itself an implementable guarantee. We therefore introduce covariance-based trust-region projection and an innovation gate as observable risk controls and prove a conditional mean-square boundedness result. The construction is instantiated by an ANFIS residual model applied to a parameter-augmented UKF. Corrected SOC, together with four explicitly defined health indices, feeds a second ANFIS stage for SOH. Evaluation uses a structurally distinct 2RC-hysteresis data generator, a 24-month ageing horizon, disjoint train/validation/test profiles, and paired repeated-Monte-Carlo analysis. Across eleven estimators (the proposed method plus ten baselines, including a protocol-matched implementation of the published EKF-ANN architecture of Dao et al.), the proposed SOC estimator obtained the lowest RMSE, 0.942 %, versus 1.314 % for its UKF baseline and 1.022 % for the linear-correction ablation. The test-set alignment coefficient was 0.716, corresponding to an optimal attainable RMSE reduction of 30.2 %; the validation-scaled correction achieved 28.3 %. Under a sign-reversed stress test, strict projection and gating reduced the damage relative to an ungated correction but did not preserve baseline RMSE, confirming that the online controls are risk-limiting surrogates rather than a pointwise guarantee. The SOH ANFIS stage was outperformed by a linear corrector, which is reported as a limitation.

Mathematical Models in Engineering
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Pointwise and mean-square conditions for residual correction of state estimators: a trust-region UKF–ANFIS framework for cascaded SOC and SOH estimation in VRLA gel batteries — Каримберди Каршиев, Igor Kolesnikov, et al. · Mathematical Models in Engineering (2026) | TGRS Research Map | TGRS