Unlocking public EV charging flexibility for grid balancing: A year-long empirical assessment of unidirectional and bidirectional smart charging in Prague

The transition of imbalance settlement in the Continental Europe synchronous area to 15-minute market time units, together with rising shares of variable renewable generation, raises the operational value of sub-hourly demand-side flexibility. Electric vehicles at public charging stations are an attractive source, yet empirical estimates of the balancing value of public smart charging remain scarce. This paper quantifies the technical potential of aggregated public smart charging in Prague to absorb the 15-minute system imbalance of the Czech transmission system operator ČEPS, using a full year of real charging-session data: 286,492 sessions across 1051 charging points. An ex-post optimization on a session-level flexibility envelope evaluates four configurations: the unidirectional (V1G) and bidirectional (V2G) operating modes, each under two user-comfort scenarios in which the delivered energy is preserved exactly (S1) or relaxed to the greater of 80% of it or 30 kWh (S2). The fleet’s uncontrolled load is removed first, so the same energy is re-timed, not added. Public V1G absorbs 4.44% of the imbalance energy under S1 and 4.85% under S2; V2G absorbs 7.09% and 7.64%. Bidirectional operation increases the absorbed energy by more than half, whereas relaxing comfort adds only about half a percentage point, so the bidirectional-infrastructure axis carries far more value than the user-incentive axis. These figures are a best-case ceiling computed with hindsight, not an operational forecast; valued at Czech final settlement prices, the V2G potential is a gross avoided balancing cost of up to about EUR 480,000 per year.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2026-11-23
DOI
https://doi.org/10.1016/j.apenergy.2026.129307
Primary Topic
Electric Vehicles and Infrastructure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Unlocking public EV charging flexibility for grid balancing: A year-long empirical assessment of unidirectional and bidirectional smart charging in Prague

Michaela Valentová, Marek Miltner, Ondřej Štogl, Oldřich Starý et al.
Applied Energy
Electric Vehicles and Infrastructure
article

Unlocking public EV charging flexibility for grid balancing: A year-long empirical assessment of unidirectional and bidirectional smart charging in Prague

Michaela Valentová, Marek Miltner, Ondřej Štogl, Oldřich Starý, Martin Tichý, Jakub Zíka
article en

Abstract

The transition of imbalance settlement in the Continental Europe synchronous area to 15-minute market time units, together with rising shares of variable renewable generation, raises the operational value of sub-hourly demand-side flexibility. Electric vehicles at public charging stations are an attractive source, yet empirical estimates of the balancing value of public smart charging remain scarce. This paper quantifies the technical potential of aggregated public smart charging in Prague to absorb the 15-minute system imbalance of the Czech transmission system operator ČEPS, using a full year of real charging-session data: 286,492 sessions across 1051 charging points. An ex-post optimization on a session-level flexibility envelope evaluates four configurations: the unidirectional (V1G) and bidirectional (V2G) operating modes, each under two user-comfort scenarios in which the delivered energy is preserved exactly (S1) or relaxed to the greater of 80% of it or 30 kWh (S2). The fleet’s uncontrolled load is removed first, so the same energy is re-timed, not added. Public V1G absorbs 4.44% of the imbalance energy under S1 and 4.85% under S2; V2G absorbs 7.09% and 7.64%. Bidirectional operation increases the absorbed energy by more than half, whereas relaxing comfort adds only about half a percentage point, so the bidirectional-infrastructure axis carries far more value than the user-incentive axis. These figures are a best-case ceiling computed with hindsight, not an operational forecast; valued at Czech final settlement prices, the V2G potential is a gross avoided balancing cost of up to about EUR 480,000 per year.

Applied EnergyVol. 428
Czech Technical University in Prague (CZ), RWTH Aachen University (DE), Stanford University (US)
České Vysoké Učení Technické v Praze
Electric Vehicles and Infrastructure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon