Bidirectional Wireless Power Transfer for Vehicle-to-Grid Services: Converter Control, Power Quality and Grid-Interface Behaviour

Bidirectional wireless power transfer lets parked electric vehicles provide vehicle-to-grid (V2G) services without a plug, but its converter control and grid-interface behaviour have rarely been studied together. This paper presents a simulation-based study of a 7.7-kW, 85-kHz double-sided inductor-capacitor-capacitor (LCC) wireless charger connected to a 230-V, 50-Hz single-phase grid through an LCL-filtered active front end. A fundamental and multi-harmonic model of the wireless link is derived and cross-checked against 240 switching-level MATLAB/Simulink operating points (mean power error 0.26%, maximum 3.5%). Single-, dual- and zero-voltage-switching (ZVS)-constrained triple-phase-shift (SPS, DPS, TPS) modulation are synthesised by optimisation and embedded in a cascaded controller with a second-order-generalised-integrator-phase-locked loop (SOGI-PLL), DC-link power feed-forward, proportional-resonant current control and IEEE Std 1547-2018 frequency-watt and volt-var functions. With SPS, the grid-to-battery efficiency at 1.54 kW is 69.8% (charging) and 59.7% (V2G); DPS and TPS raise it above 90% and reach 91.8%–92.2% at rated power, TPS avoiding hard switching at every simulated point, with partial ZVS at some edges. The charger reverses its ±7.7-kW range within 22 ms at the grid, keeps the current total demand distortion (TDD) below 0.8% with a distorted grid voltage, follows the frequency-watt droop within 40 ms and supplies four-quadrant reactive power without cycling the battery. On a weak feeder, volt-var control moves the voltage from 0.930 to 0.945 p.u. in charging and from 1.050 to 1.041 p.u. in V2G, provided the grid-voltage feed-forward is limited to the fundamental. The simulations indicate that a bidirectional wireless charger with variable-pulse-width modulation can act as an efficient, fast and grid-friendly V2G resource.

Authors

Institutions

Publication Details

Journal
Electrical Engineering and Energy (ELENE)
Published
2026-11-23
DOI
https://doi.org/10.64470/elene.2026.51
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Bidirectional Wireless Power Transfer for Vehicle-to-Grid Services: Converter Control, Power Quality and Grid-Interface Behaviour

Taofeek Lawal, Victor Ogunyemi
Electrical Engineering and Energy (ELENE)
Wireless Power Transfer Systems
article

Bidirectional Wireless Power Transfer for Vehicle-to-Grid Services: Converter Control, Power Quality and Grid-Interface Behaviour

Taofeek Lawal, Victor Ogunyemi
article en

Abstract

Bidirectional wireless power transfer lets parked electric vehicles provide vehicle-to-grid (V2G) services without a plug, but its converter control and grid-interface behaviour have rarely been studied together. This paper presents a simulation-based study of a 7.7-kW, 85-kHz double-sided inductor-capacitor-capacitor (LCC) wireless charger connected to a 230-V, 50-Hz single-phase grid through an LCL-filtered active front end. A fundamental and multi-harmonic model of the wireless link is derived and cross-checked against 240 switching-level MATLAB/Simulink operating points (mean power error 0.26%, maximum 3.5%). Single-, dual- and zero-voltage-switching (ZVS)-constrained triple-phase-shift (SPS, DPS, TPS) modulation are synthesised by optimisation and embedded in a cascaded controller with a second-order-generalised-integrator-phase-locked loop (SOGI-PLL), DC-link power feed-forward, proportional-resonant current control and IEEE Std 1547-2018 frequency-watt and volt-var functions. With SPS, the grid-to-battery efficiency at 1.54 kW is 69.8% (charging) and 59.7% (V2G); DPS and TPS raise it above 90% and reach 91.8%–92.2% at rated power, TPS avoiding hard switching at every simulated point, with partial ZVS at some edges. The charger reverses its ±7.7-kW range within 22 ms at the grid, keeps the current total demand distortion (TDD) below 0.8% with a distorted grid voltage, follows the frequency-watt droop within 40 ms and supplies four-quadrant reactive power without cycling the battery. On a weak feeder, volt-var control moves the voltage from 0.930 to 0.945 p.u. in charging and from 1.050 to 1.041 p.u. in V2G, provided the grid-voltage feed-forward is limited to the fundamental. The simulations indicate that a bidirectional wireless charger with variable-pulse-width modulation can act as an efficient, fast and grid-friendly V2G resource.

Electrical Engineering and Energy (ELENE)Vol. 6(1)
Olabisi Onabanjo University (NG)
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics