Effects of implantoplasty on titanium dental implant corrosion, cytotoxicity and extracellular matrix proteins (collagen 1, 3, and elastin) under in vitro conditions

Implantoplasty (IP) is a commonly employed mechanical technique to remove bacterial biofilms adhering to the titanium surfaces of dental implants. Based on the intraoral machining and smoothing of the titanium surface using rotating instruments, this procedure inevitably alters the physicochemical properties of the implant. Therefore, the aim of this study is to evaluate the effects of implant surface modifications on corrosion resistance, cell viability (via MTT assay), and implant-tissue interface stability (by analyzing collagen type 1, collagen type 3, and elastin expression) in comparison with untreated control samples. Using tungsten carbide burs and silicon carbide polishers, implantoplasty was performed to simulate a 5 mm bone loss in the SLA surface area of dental implants. Surface topography (S a ) was determined using a 3D profilometer. Corrosion resistance was evaluated using electrochemical tests in Hank’s solution. Corrosion parameters such as corrosion current density (i corr ), and corrosion potential (Ecorr), were determined. The effects of implants on cell viability were analyzed using the MTT test. In addition, collagen type 1, type 3 and elastin levels were evaluated using ELISA to determine implant-tissue interface stability. Although implantoplasty significantly reduced surface roughness and increased the initial corrosion rate approximately sevenfold compared to SLA controls, cell viability remained well above the 70% cytocompatibility threshold across all groups. These findings suggest that despite the altered initial electrochemical parameters, the modified surfaces exert no cytotoxic effects on fibroblast cells, demonstrating favorable short-term in vitro cytocompatibility.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2026-11-23
DOI
https://doi.org/10.1177/09544119261507533
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effects of implantoplasty on titanium dental implant corrosion, cytotoxicity and extracellular matrix proteins (collagen 1, 3, and elastin) under in vitro conditions

Cenk Fatih Çanakçı, Mevlüt Furkan Sadeler
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Dental Implant Techniques and Outcomes
article

Effects of implantoplasty on titanium dental implant corrosion, cytotoxicity and extracellular matrix proteins (collagen 1, 3, and elastin) under in vitro conditions

Cenk Fatih Çanakçı, Mevlüt Furkan Sadeler
article en

Abstract

Implantoplasty (IP) is a commonly employed mechanical technique to remove bacterial biofilms adhering to the titanium surfaces of dental implants. Based on the intraoral machining and smoothing of the titanium surface using rotating instruments, this procedure inevitably alters the physicochemical properties of the implant. Therefore, the aim of this study is to evaluate the effects of implant surface modifications on corrosion resistance, cell viability (via MTT assay), and implant-tissue interface stability (by analyzing collagen type 1, collagen type 3, and elastin expression) in comparison with untreated control samples. Using tungsten carbide burs and silicon carbide polishers, implantoplasty was performed to simulate a 5 mm bone loss in the SLA surface area of dental implants. Surface topography (S a ) was determined using a 3D profilometer. Corrosion resistance was evaluated using electrochemical tests in Hank’s solution. Corrosion parameters such as corrosion current density (i corr ), and corrosion potential (Ecorr), were determined. The effects of implants on cell viability were analyzed using the MTT test. In addition, collagen type 1, type 3 and elastin levels were evaluated using ELISA to determine implant-tissue interface stability. Although implantoplasty significantly reduced surface roughness and increased the initial corrosion rate approximately sevenfold compared to SLA controls, cell viability remained well above the 70% cytocompatibility threshold across all groups. These findings suggest that despite the altered initial electrochemical parameters, the modified surfaces exert no cytotoxic effects on fibroblast cells, demonstrating favorable short-term in vitro cytocompatibility.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Atatürk University (TR)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines