Activity apportioning models following multi-compartment dosimetry for radioembolization of liver tumors supplied by multiple arteries

To develop activity apportioning models for applying multi-compartment dosimetry (MCD) in multi-vessel cases and to evaluate them under different lung shunt fraction (LSF) assumptions. Three models to apportion the total activity determined by global MCD across multiple segments were introduced: MCD considering segment-specific LSFs (MCD- LSF j ), MCD assuming a uniform LSF across segments (MCD- \( \overline{{LSF}} \) ), and a method that distributes the total activity in proportion to the perfused volume of each segment (PV- \( \overline{{LSF}} \) ). In the two former methods, activity was apportioned in proportion to the tumor-to-normal liver ratio (R)–weighted volume (RWV) of each segment, calculated by “R × tumor volume + non-tumor liver volume” for that segment. The discrepancies in segmental activity estimates among these models were evaluated using analytic methods and Monte Carlo (MC) simulation to generate 10,000 virtual patients with 2–5 uneven tumor-bearing segments. According to the analytic methods, the probability that the relative difference of segmental activities calculated by MCD- \( \overline{{LSF}} \) and MCD- \(\:{LSF}_{j}\) exceeds 15% was approximately 0.05%. According to the MC simulation, the mean relative and maximum differences of segmental activity estimates by MCD- \(\:{LSF}_{j}\) and MCD- \( \overline{{LSF}} \) were 1.32% (95% confidence interval [CI], 1.29–1.35) and 23.4% (95% CI, 18.0–33.1), respectively. The mean relative and maximum differences between MCD- \(\:{LSF}_{j}\) and PV- \( \overline{{LSF}} \) were 13.3% (95% CI, 13.1–13.5) and 198.1% (95% CI, 168.1–240.0), respectively. Activity apportioning models based on RWV enable the practical application of MCD in liver cancers with multiple tumor-supplying arteries, and segment-specific LSFs can be substituted with the global LSF.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2026-11-23
DOI
https://doi.org/10.1186/s40658-026-00966-1
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Activity apportioning models following multi-compartment dosimetry for radioembolization of liver tumors supplied by multiple arteries

Minseok Suh, Jin Woo Choi, Juil Park, Kwan‐Young Bak et al.
EJNMMI Physics
Radiopharmaceutical Chemistry and Applications
article

Activity apportioning models following multi-compartment dosimetry for radioembolization of liver tumors supplied by multiple arteries

Minseok Suh, Jin Woo Choi, Juil Park, Kwan‐Young Bak, Gyeongmin Kim, Anshul Chabra
article en

Abstract

To develop activity apportioning models for applying multi-compartment dosimetry (MCD) in multi-vessel cases and to evaluate them under different lung shunt fraction (LSF) assumptions. Three models to apportion the total activity determined by global MCD across multiple segments were introduced: MCD considering segment-specific LSFs (MCD- LSF j ), MCD assuming a uniform LSF across segments (MCD- \( \overline{{LSF}} \) ), and a method that distributes the total activity in proportion to the perfused volume of each segment (PV- \( \overline{{LSF}} \) ). In the two former methods, activity was apportioned in proportion to the tumor-to-normal liver ratio (R)–weighted volume (RWV) of each segment, calculated by “R × tumor volume + non-tumor liver volume” for that segment. The discrepancies in segmental activity estimates among these models were evaluated using analytic methods and Monte Carlo (MC) simulation to generate 10,000 virtual patients with 2–5 uneven tumor-bearing segments. According to the analytic methods, the probability that the relative difference of segmental activities calculated by MCD- \( \overline{{LSF}} \) and MCD- \(\:{LSF}_{j}\) exceeds 15% was approximately 0.05%. According to the MC simulation, the mean relative and maximum differences of segmental activity estimates by MCD- \(\:{LSF}_{j}\) and MCD- \( \overline{{LSF}} \) were 1.32% (95% confidence interval [CI], 1.29–1.35) and 23.4% (95% CI, 18.0–33.1), respectively. The mean relative and maximum differences between MCD- \(\:{LSF}_{j}\) and PV- \( \overline{{LSF}} \) were 13.3% (95% CI, 13.1–13.5) and 198.1% (95% CI, 168.1–240.0), respectively. Activity apportioning models based on RWV enable the practical application of MCD in liver cancers with multiple tumor-supplying arteries, and segment-specific LSFs can be substituted with the global LSF.

EJNMMI Physics
Seoul National University (KR), Sungshin Women's University (KR), Yonsei University (KR), Severance Hospital (KR), Seoul National University Hospital (KR), Boston Scientific (United States) (US)
National Research Foundation of Korea
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon