Limiter-aware reset control of the power synchronization loop for fault recovery of grid-forming inverters

Grid-forming inverters synchronize through a power synchronization loop whose damping falls as the grid becomes stronger and whose transient stability suffers when a fault drives the converter into current limiting. This paper proposes a reset controller for this loop. A constant-in-gain lead-in-phase (CgLp) element, formed by a lead filter followed by a first-order reset element, replaces the linear droop path, so that a reset at a zero crossing of the power error clears the frequency deviation accumulated during a disturbance. A limiter-aware rule adds resets on the unfiltered power error while the current limiter is active. Outside current limiting, stability of the reset loop is certified with the H β condition for short-circuit ratios from 1.5 to 50. The controller is compared with droop control, two lead compensators, and two virtual synchronous generator damping schemes, all tuned by one rule. On an averaged model it raises the critical clearing time of balanced dips by 42%-84% relative to droop control, and, together with the alternating-inertia scheme, it is the only design that rides through a 120 ms bolted dip at a short-circuit ratio of 10. A switching converter model with an LCL filter reproduces the averaged results within 0.2 percentage points of overshoot at a short-circuit ratio of 2. In a modified IEEE 9-bus system, post-fault power recovery falls from 0.73–0.84 s to 0.29 s. Frequency ramps, during which the power error keeps one sign and no reset occurs, remain a limitation.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11442854/v1
Primary Topic
Microgrid Control and Optimization
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Limiter-aware reset control of the power synchronization loop for fault recovery of grid-forming inverters

Muzeeb Khan Patan
Research Square
Microgrid Control and Optimization
preprint

Limiter-aware reset control of the power synchronization loop for fault recovery of grid-forming inverters

Muzeeb Khan Patan
preprint en

Abstract

Grid-forming inverters synchronize through a power synchronization loop whose damping falls as the grid becomes stronger and whose transient stability suffers when a fault drives the converter into current limiting. This paper proposes a reset controller for this loop. A constant-in-gain lead-in-phase (CgLp) element, formed by a lead filter followed by a first-order reset element, replaces the linear droop path, so that a reset at a zero crossing of the power error clears the frequency deviation accumulated during a disturbance. A limiter-aware rule adds resets on the unfiltered power error while the current limiter is active. Outside current limiting, stability of the reset loop is certified with the H β condition for short-circuit ratios from 1.5 to 50. The controller is compared with droop control, two lead compensators, and two virtual synchronous generator damping schemes, all tuned by one rule. On an averaged model it raises the critical clearing time of balanced dips by 42%-84% relative to droop control, and, together with the alternating-inertia scheme, it is the only design that rides through a 120 ms bolted dip at a short-circuit ratio of 10. A switching converter model with an LCL filter reproduces the averaged results within 0.2 percentage points of overshoot at a short-circuit ratio of 2. In a modified IEEE 9-bus system, post-fault power recovery falls from 0.73–0.84 s to 0.29 s. Frequency ramps, during which the power error keeps one sign and no reset occurs, remain a limitation.

Research Square
University of Technology and Applied Sciences, Muscat (OM), University of Technology and Applied Sciences (OM)
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon