A Weighted Graph Ensemble Approach for EEG–EOG-Based Motor Imagery Classification and Robot Command Generation

Brain-computer interface (BCI) systems require reliable decoding of motor imagery despite significant variability between subjects, non-stationarity, and complex inter-physiological pathways. This study presents a weighted ensemble framework, graphically based for the multimodal EEG-OG classification of motor imagery and the generation of robotic commands. The framework represents the synchronous EEG and EOG channels as a single graph, quantifies pairwise channel relationships by Pearson correlation, extracts graph topological descriptors that can be interpreted, performs a training fold selection of features, and combines heterogeneous classifiers by weighting probabilities based on performance. The evaluation distinguishes a primary four-class benchmark from a separate 50-subject secondary cohort. On the primary BCI Competition IV Dataset 2a benchmark, the performance-weighted ensemble achieved 86.7% accuracy, with 81.4%, 78.9%, and 83.1% obtained by SVM, random forest, and XGBoost, respectively. On the independent 50-subject acute stroke motor imagery cohort, a separate within-cohort LOSO analysis yielded 84.4% for EEG-only, 90.7% for EOG-only, 84.3% for EOG-controlled EEG, and 93.0% for the combined EEG–EOG configuration, corresponding to an 8.6 percentage point improvement over EEG-only processing. Threshold sensitivity ranged from 91.8% to 93.0%, while the weighted graph reached 93.4% compared with 93.0% for the binary graph. A cross-dataset external validation experiment trained a binary left-hand versus right-hand model on the primary Dataset 2a training data and evaluated the frozen model on the independent 50-subject acute stroke cohort without target cohort retraining or calibration; the proposed ensemble achieved 86.1% accuracy. The results support the utility of a unified multimodal graph representation while also demonstrating that the predictive contribution of EOG must be interpreted carefully because ocular and task-correlated activity may contribute to the observed gain.

Authors

Institutions

Publication Details

Journal
Technologies
Published
2026-11-23
DOI
https://doi.org/10.3390/technologies14120782
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Weighted Graph Ensemble Approach for EEG–EOG-Based Motor Imagery Classification and Robot Command Generation

Mustafa J. Hayawi, Raid Luaibi Lafta, Azhaar Abdalhussan Shalal
Technologies
EEG and Brain-Computer Interfaces
article

A Weighted Graph Ensemble Approach for EEG–EOG-Based Motor Imagery Classification and Robot Command Generation

Mustafa J. Hayawi, Raid Luaibi Lafta, Azhaar Abdalhussan Shalal
article en

Abstract

Brain-computer interface (BCI) systems require reliable decoding of motor imagery despite significant variability between subjects, non-stationarity, and complex inter-physiological pathways. This study presents a weighted ensemble framework, graphically based for the multimodal EEG-OG classification of motor imagery and the generation of robotic commands. The framework represents the synchronous EEG and EOG channels as a single graph, quantifies pairwise channel relationships by Pearson correlation, extracts graph topological descriptors that can be interpreted, performs a training fold selection of features, and combines heterogeneous classifiers by weighting probabilities based on performance. The evaluation distinguishes a primary four-class benchmark from a separate 50-subject secondary cohort. On the primary BCI Competition IV Dataset 2a benchmark, the performance-weighted ensemble achieved 86.7% accuracy, with 81.4%, 78.9%, and 83.1% obtained by SVM, random forest, and XGBoost, respectively. On the independent 50-subject acute stroke motor imagery cohort, a separate within-cohort LOSO analysis yielded 84.4% for EEG-only, 90.7% for EOG-only, 84.3% for EOG-controlled EEG, and 93.0% for the combined EEG–EOG configuration, corresponding to an 8.6 percentage point improvement over EEG-only processing. Threshold sensitivity ranged from 91.8% to 93.0%, while the weighted graph reached 93.4% compared with 93.0% for the binary graph. A cross-dataset external validation experiment trained a binary left-hand versus right-hand model on the primary Dataset 2a training data and evaluated the frozen model on the independent 50-subject acute stroke cohort without target cohort retraining or calibration; the proposed ensemble achieved 86.1% accuracy. The results support the utility of a unified multimodal graph representation while also demonstrating that the predictive contribution of EOG must be interpreted carefully because ocular and task-correlated activity may contribute to the observed gain.

TechnologiesVol. 14(12)
University of Shatrah (IQ)
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A Weighted Graph Ensemble Approach for EEG–EOG-Based Motor Imagery Classification and Robot Command Generation — Mustafa J. Hayawi, Raid Luaibi Lafta, et al. · Technologies (2026) | TGRS Research Map | TGRS