A sensitive LC-TQ-MS/MS approach for simultaneous trace-level quantification of iptacopan N-Nitrosamine impurities

N-Nitrosamine drug substance-related impurities (NDSRIs) have become an important concern in pharmaceutical quality control because of their potential carcinogenic risk and stringent acceptable intake (AI) limits. The objective of this investigation was to establish a sensitive, selective, and efficient LC–TQ–MS/MS analytical method for the concurrent determination of trace concentrations of N-nitroso Iptacopan impurity-1 (N-NIPC-1) and N-nitroso Iptacopan impurity-2 (N-NIPC-2) in Iptacopan (IPC) drug substance, a complement factor B inhibitor. As per the CPC Approach, the both N-nitrosamine impurities were classified as potency category 4, with an acceptable intake (AI) limit of 1500 ng day-1 assigned to each impurity. The analytes were separated using an Agilent Eclipse EC-C18 column (150 × 4.6 mm, 2.7 µm) with a gradient mobile phase system comprising 0.1% formic acid in water and 0.1% formic acid in acetonitrile at a flow rate of 0.4 mL min-¹. Mass spectrometric detection is carried out using positive mode electrospray ionization (ESI+) with Multiple Reaction Monitoring (MRM) for selective quantification. The MRM transitions selected for N-NIPC-1 were m/z 279.08 → 249.11 (quantifier) and m/z 279.08 → 176.10 (qualifier). For N-NIPC-2, the corresponding transitions were m/z 293.13 → 263.10 and m/z 293.13 → 190.08, respectively. The proposed method is validated in compliance with ICH Q2 (R2), and the evaluated validation characteristics satisfied the predetermined acceptance criteria, demonstrating adequate specificity, sensitivity, linearity, accuracy, precision, robustness, and solution stability. The method was successfully applied to the analysis of commercial IPC drug substance batches, confirming its suitability for trace-level monitoring of the investigated NDSRIs. The established LC–TQ-MS/MS procedure offers a robust and sensitive analytical method for routine quality control testing and risk-based surveillance of N-NIPC-1 and N-NIPC-2 in Iptacopan drug substance, supporting effective control of these nitrosamine impurities.

Authors

Publication Details

Journal
Figshare
Published
2026-11-23
DOI
https://doi.org/10.6084/m9.figshare.35086781
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A sensitive LC-TQ-MS/MS approach for simultaneous trace-level quantification of iptacopan N-Nitrosamine impurities

K. Ramakrishna Reddy, Anwar Sulaiman KC
Figshare
Analytical Methods in Pharmaceuticals
article

A sensitive LC-TQ-MS/MS approach for simultaneous trace-level quantification of iptacopan N-Nitrosamine impurities

K. Ramakrishna Reddy, Anwar Sulaiman KC
article en

Abstract

N-Nitrosamine drug substance-related impurities (NDSRIs) have become an important concern in pharmaceutical quality control because of their potential carcinogenic risk and stringent acceptable intake (AI) limits. The objective of this investigation was to establish a sensitive, selective, and efficient LC–TQ–MS/MS analytical method for the concurrent determination of trace concentrations of N-nitroso Iptacopan impurity-1 (N-NIPC-1) and N-nitroso Iptacopan impurity-2 (N-NIPC-2) in Iptacopan (IPC) drug substance, a complement factor B inhibitor. As per the CPC Approach, the both N-nitrosamine impurities were classified as potency category 4, with an acceptable intake (AI) limit of 1500 ng day-1 assigned to each impurity. The analytes were separated using an Agilent Eclipse EC-C18 column (150 × 4.6 mm, 2.7 µm) with a gradient mobile phase system comprising 0.1% formic acid in water and 0.1% formic acid in acetonitrile at a flow rate of 0.4 mL min-¹. Mass spectrometric detection is carried out using positive mode electrospray ionization (ESI+) with Multiple Reaction Monitoring (MRM) for selective quantification. The MRM transitions selected for N-NIPC-1 were m/z 279.08 → 249.11 (quantifier) and m/z 279.08 → 176.10 (qualifier). For N-NIPC-2, the corresponding transitions were m/z 293.13 → 263.10 and m/z 293.13 → 190.08, respectively. The proposed method is validated in compliance with ICH Q2 (R2), and the evaluated validation characteristics satisfied the predetermined acceptance criteria, demonstrating adequate specificity, sensitivity, linearity, accuracy, precision, robustness, and solution stability. The method was successfully applied to the analysis of commercial IPC drug substance batches, confirming its suitability for trace-level monitoring of the investigated NDSRIs. The established LC–TQ-MS/MS procedure offers a robust and sensitive analytical method for routine quality control testing and risk-based surveillance of N-NIPC-1 and N-NIPC-2 in Iptacopan drug substance, supporting effective control of these nitrosamine impurities.

Figshare
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A sensitive LC-TQ-MS/MS approach for simultaneous trace-level quantification of iptacopan N-Nitrosamine impurities — K. Ramakrishna Reddy, Anwar Sulaiman KC · Figshare (2026) | TGRS Research Map | TGRS