Bézier Curve–Based Quantitative Eyelid Symmetry Analysis and Artificial Intelligence–Assisted Photographic Assessment After Upper Eyelid Surgery: A Prospective Study

Background To investigate the potential of Bézier curve–based quantitative analyses of bilateral eyelid margin and contour-shape symmetry for assessing surgical outcomes after upper eyelid surgery, and to examine their associations with assessments by experienced oculoplastic surgeons and artificial intelligence (AI)–generated photographic outcome scores. Methods This prospective, single-center study included 67 patients who underwent Müller muscle–conjunctival resection (MMCR; n = 26), external levator resection (n = 20), or bilateral functional upper eyelid blepharoplasty (n = 21). Preoperative and 6-month postoperative photographs were analyzed using pupil-centered and eyelid-apex height–equalized Bézier curve alignments. Mean absolute error (MAE), mean squared error (MSE), root mean squared error (RMSE), and coefficient of determination (R²) were calculated. Associations with the assessments of two oculoplastic surgeons and AI-generated photographic scores were examined using Spearman correlation analysis. Results In the pupil-centered analysis, MAE decreased from 1.1 ± 0.8 to 0.8 ± 0.6 and RMSE decreased from 1.2 ± 0.8 to 0.9 ± 0.6, whereas R² increased from − 1.5 ± 4.2 to 0.2 ± 1.2 (all p < 0.001). Changes in the eyelid-apex height–equalized contour analysis were not significant (all p > 0.05). Postoperative pupil-centered R² correlated positively with surgeons’ overall outcome ratings (ρ = 0.543) and AI-generated scores (ρ = 0.570; both p < 0.001). The overall correlation between surgeon and AI scores was ρ = 0.760 (p < 0.001). Conclusions Pupil-centered Bézier curve–based measures of bilateral eyelid margin symmetry showed significant postoperative improvement and were associated with surgical outcome assessments by experienced oculoplastic surgeons. AI-assisted photographic scores were also positively correlated with surgeons’ assessments. These findings provide a promising basis for developing more comprehensive and standardized approaches that combine quantitative symmetry analysis with AI-assisted photographic evaluation to complement conventional margin reflex distance-1 (MRD1) measurement in the assessment of upper eyelid surgical outcomes.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11526076/v1
Primary Topic
Ophthalmology and Eye Disorders
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Bézier Curve–Based Quantitative Eyelid Symmetry Analysis and Artificial Intelligence–Assisted Photographic Assessment After Upper Eyelid Surgery: A Prospective Study

Said Kemal Cengiz, Fatma Selin Kaya, Gülistan Oyur, Kübra Şerefoğlu Çabuk et al.
Research Square
Ophthalmology and Eye Disorders
preprint

Bézier Curve–Based Quantitative Eyelid Symmetry Analysis and Artificial Intelligence–Assisted Photographic Assessment After Upper Eyelid Surgery: A Prospective Study

Said Kemal Cengiz, Fatma Selin Kaya, Gülistan Oyur, Kübra Şerefoğlu Çabuk, Muzaffer Said Güler, Fatma Savur
preprint en

Abstract

Background To investigate the potential of Bézier curve–based quantitative analyses of bilateral eyelid margin and contour-shape symmetry for assessing surgical outcomes after upper eyelid surgery, and to examine their associations with assessments by experienced oculoplastic surgeons and artificial intelligence (AI)–generated photographic outcome scores. Methods This prospective, single-center study included 67 patients who underwent Müller muscle–conjunctival resection (MMCR; n = 26), external levator resection (n = 20), or bilateral functional upper eyelid blepharoplasty (n = 21). Preoperative and 6-month postoperative photographs were analyzed using pupil-centered and eyelid-apex height–equalized Bézier curve alignments. Mean absolute error (MAE), mean squared error (MSE), root mean squared error (RMSE), and coefficient of determination (R²) were calculated. Associations with the assessments of two oculoplastic surgeons and AI-generated photographic scores were examined using Spearman correlation analysis. Results In the pupil-centered analysis, MAE decreased from 1.1 ± 0.8 to 0.8 ± 0.6 and RMSE decreased from 1.2 ± 0.8 to 0.9 ± 0.6, whereas R² increased from − 1.5 ± 4.2 to 0.2 ± 1.2 (all p < 0.001). Changes in the eyelid-apex height–equalized contour analysis were not significant (all p > 0.05). Postoperative pupil-centered R² correlated positively with surgeons’ overall outcome ratings (ρ = 0.543) and AI-generated scores (ρ = 0.570; both p < 0.001). The overall correlation between surgeon and AI scores was ρ = 0.760 (p < 0.001). Conclusions Pupil-centered Bézier curve–based measures of bilateral eyelid margin symmetry showed significant postoperative improvement and were associated with surgical outcome assessments by experienced oculoplastic surgeons. AI-assisted photographic scores were also positively correlated with surgeons’ assessments. These findings provide a promising basis for developing more comprehensive and standardized approaches that combine quantitative symmetry analysis with AI-assisted photographic evaluation to complement conventional margin reflex distance-1 (MRD1) measurement in the assessment of upper eyelid surgical outcomes.

Research Square
Yıldız Technical University (TR), Sağlık Bilimleri Üniversitesi (TR), İstanbul Kanuni Sultan Süleyman Eğitim ve Araştırma Hastanesi (TR)
Ophthalmology and Eye Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon