CRANIS: Cortex- and Resection-Aware Automated Neurosurgical Image Segmentation

Background/Objectives: In image-guided neurosurgery, brain shift degrades the accuracy of preoperative image-based navigation. Image updating addresses this by deforming preoperative images to match intraoperative anatomy using computational models driven by data such as intraoperative stereovision (iSV). However, these pipelines rely on user intervention, limiting wider adoption. In particular, cortex and resection cavity areas define boundary conditions, model tissue removal, and measure cortical shift, yet automatic segmentation remains challenging, and inaccuracies can limit image updating performance. Methods: We present cortex- and resection-aware automated neurosurgical image segmentation (CRANIS), which extracts features from color and disparity images with Swin transformers and then fuses and decodes them via a holistically nested edge detection architecture to segment the cortex and resection cavity from iSV. Our dataset consisted of 231 cortex and 171 resection cavity cases (20% held-out test set and five-fold cross-validation on the remaining 80%). To demonstrate that CRANIS segmentations produce comparable image updating results to manual delineations, CRANIS was also integrated into the image updating pipelines in five representative test cases for initial exposure. Results: CRANIS achieved median Dice similarity coefficient (DSC) values of 0.97 (cortex) and 0.85 (resection) with an average computational time of 1.67 s per image. Image updating with CRANIS achieved an average surface target registration error of 1.8 ± 1.1 mm, which is comparable to that of manual delineation (1.9 ± 1.0 mm). Even the worst-performing resection-stage case (DSC = 0.53) produced comparable results (1.8 ± 0.1 mm). Conclusions: By eliminating manual segmentation, CRANIS supports future wider adoption of image updating in neuro-navigation.

Authors

Institutions

Publication Details

Journal
Neuroimaging
Published
2026-11-23
DOI
https://doi.org/10.3390/neuroimaging1040019
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

CRANIS: Cortex- and Resection-Aware Automated Neurosurgical Image Segmentation

Bashirul Azam Biswas, David W. Roberts, Keith D. Paulsen, William R. Warner et al.
Neuroimaging
Medical Image Segmentation Techniques
article

CRANIS: Cortex- and Resection-Aware Automated Neurosurgical Image Segmentation

Bashirul Azam Biswas, David W. Roberts, Keith D. Paulsen, William R. Warner, Xiaoyao Fan, Linton T. Evans, Indrani Bhattacharya, Scott C. Davis, Chengpei Li
article en

Abstract

Background/Objectives: In image-guided neurosurgery, brain shift degrades the accuracy of preoperative image-based navigation. Image updating addresses this by deforming preoperative images to match intraoperative anatomy using computational models driven by data such as intraoperative stereovision (iSV). However, these pipelines rely on user intervention, limiting wider adoption. In particular, cortex and resection cavity areas define boundary conditions, model tissue removal, and measure cortical shift, yet automatic segmentation remains challenging, and inaccuracies can limit image updating performance. Methods: We present cortex- and resection-aware automated neurosurgical image segmentation (CRANIS), which extracts features from color and disparity images with Swin transformers and then fuses and decodes them via a holistically nested edge detection architecture to segment the cortex and resection cavity from iSV. Our dataset consisted of 231 cortex and 171 resection cavity cases (20% held-out test set and five-fold cross-validation on the remaining 80%). To demonstrate that CRANIS segmentations produce comparable image updating results to manual delineations, CRANIS was also integrated into the image updating pipelines in five representative test cases for initial exposure. Results: CRANIS achieved median Dice similarity coefficient (DSC) values of 0.97 (cortex) and 0.85 (resection) with an average computational time of 1.67 s per image. Image updating with CRANIS achieved an average surface target registration error of 1.8 ± 1.1 mm, which is comparable to that of manual delineation (1.9 ± 1.0 mm). Even the worst-performing resection-stage case (DSC = 0.53) produced comparable results (1.8 ± 0.1 mm). Conclusions: By eliminating manual segmentation, CRANIS supports future wider adoption of image updating in neuro-navigation.

NeuroimagingVol. 1(4)
Dartmouth College (US), Dartmouth–Hitchcock Medical Center (US), Dartmouth Cancer Center (US)
National Institutes of Health, National Cancer Institute
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon