Three Endotracheal Cuff Pressure Management Strategies in Pigs under Simulated High-Altitude Conditions: Randomized Study
Background: Aeromedical evacuation requires advanced critical care, and precise cuff pressure management is essential for artificial airway safety. Cuff pressure is normally maintained at 25-30 cmH 2 O, but during aeromedical evacuation, the dynamic hypobaric cabin environment may alter cuff volume. According to Boyle’s law, gas expands as pressure decreases, and rapid cabin pressure changes during ascent and descent can cause pressure instability, ventilator leakage, increased risk of ventilator-associated pneumonia, and acute airway mucosal injury. Although automatic pressure regulation and water-filling methods have been explored, evidence remains limited. Methods: Twenty-four healthy adult male pigs were used to establish an artificial airway model and randomly divided into air-filled cuff group (Group A), automated cuff pressure control group (Group B), or saline-filled cuff group (Group C). Animals were exposed to a simulated high-altitude environment in a hypobaric chamber using a typical high-altitude flight profile (climb-cruise-descent). Cuff pressure was continuously monitored, and tracheal mucosal injury was assessed. Results: Cuff pressure differed significantly among the three groups in all three phases (all P < 0.001). During ascent and cruise, Group A had the highest pressure and Group B the lowest (all pairwise P < 0.05); during descent, Group B had the highest pressure, whereas Groups A and C did not differ significantly ( P = 0.984). The group×altitude and group×time interactions were significant in all phases (all P < 0.001). Group A showed significantly steeper pressure changes than Groups B and C in all three phases (all P < 0.001), whereas Groups B and C did not differ significantly. Mucosal injury was most frequent in Group A and least in Group B, without statistical significance ( P = 0.083). Conclusions: In this simulated high-altitude porcine model, automated cuff pressure control provided the most stable regulation and lowest mucosal injury, making it a favorable strategy for airway management. Conversely, air-filled cuffs performed the poorest. Saline-filled cuffs may serve as an alternative when automated devices are unavailable, though they lack active regulation. Although mucosal injury differences lacked statistical significance, larger studies with histopathological validation are required to confirm these findings.
Authors
- Xiaohua Chen
- Qiao Cheng
- Yanfang Li
- Hu Xuehui
- Rong Zhao
- Jiajia Yan
- Xiangni Lv
Institutions
- Air Force Medical University (CN)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-23
- DOI
- https://doi.org/10.21203/rs.3.rs-11421729/v1
- Primary Topic
- Airway Management and Intubation Techniques
- Type
- preprint