Structure-Adaptive Digital Image Correlation for Diagnostics of Structural Inhomogeneity in Foam Concrete

Foam concrete and equivalent classes of highly porous cementitious materials operate as fundamental components within modern construction. These applications heavily leverage their optimal strength-to-weight ratios alongside exceptional thermal insulation capacities. However, their specific spatial geometry, intrinsically formed by randomly distributed cellular structures and macro-voids, generates substantial obstacles for objective mechanical analysis. Under external loading paradigms, every individual cavity functions as an aggressive local stress concentrator. Critical strain gradients actively generate along the perimeters of these microstructural heterogeneities, initiating localized micro-cracking sequences. Optical diagnostics mapping these internal mechanisms utilizing classical Digital Image Correlation (DIC) frequently encounter algorithmic limitations. Traditional optical flow methodologies (e.g. the Farneback algorithm) rely heavily on spatial averaging of displacement fields, which invariably results in severe artificial smoothing of displacement vectors strictly along the pore and crack boundaries. To circumvent this methodological deficiency, the present research implements a tailored Structure-Adaptive Digital Image Correlation (SA-DIC) framework adjusted for foam concrete kinematics. The pipeline deploys an edge detection scan to construct a rigid binary mask outlining structural discontinuities. By integrating a geometric connectivity function, the calculation strictly blocks spatial averaging from crossing localized structural boundaries, thereby preserving physically authentic strain jumps. Method verification was conducted based on a real physical experiment: uniaxial compression of a foam concrete specimen equipped with a high-contrast speckle pattern, recorded in 4K resolution at 60 frames per second. The analysis demonstrated that the SA-DIC algorithm reduces the baseline instrumental noise floor by 19.3 % (verified via a Zero-Strain Test on stationary frames). During the active compression phase and macro-crack opening, the application of the SA-DIC method successfully reduced the level of fictitious strains within the intact matrix of the foam concrete by 25.1 % compared to the standard averaging protocol.

Authors

Institutions

Publication Details

Journal
Materials science forum
Published
2026-11-23
DOI
https://doi.org/10.4028/p-cb9kan
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Structure-Adaptive Digital Image Correlation for Diagnostics of Structural Inhomogeneity in Foam Concrete

Olena Mikulich, Nazar Martyniuk
Materials science forum
Optical measurement and interference techniques
article

Structure-Adaptive Digital Image Correlation for Diagnostics of Structural Inhomogeneity in Foam Concrete

Olena Mikulich, Nazar Martyniuk
article en

Abstract

Foam concrete and equivalent classes of highly porous cementitious materials operate as fundamental components within modern construction. These applications heavily leverage their optimal strength-to-weight ratios alongside exceptional thermal insulation capacities. However, their specific spatial geometry, intrinsically formed by randomly distributed cellular structures and macro-voids, generates substantial obstacles for objective mechanical analysis. Under external loading paradigms, every individual cavity functions as an aggressive local stress concentrator. Critical strain gradients actively generate along the perimeters of these microstructural heterogeneities, initiating localized micro-cracking sequences. Optical diagnostics mapping these internal mechanisms utilizing classical Digital Image Correlation (DIC) frequently encounter algorithmic limitations. Traditional optical flow methodologies (e.g. the Farneback algorithm) rely heavily on spatial averaging of displacement fields, which invariably results in severe artificial smoothing of displacement vectors strictly along the pore and crack boundaries. To circumvent this methodological deficiency, the present research implements a tailored Structure-Adaptive Digital Image Correlation (SA-DIC) framework adjusted for foam concrete kinematics. The pipeline deploys an edge detection scan to construct a rigid binary mask outlining structural discontinuities. By integrating a geometric connectivity function, the calculation strictly blocks spatial averaging from crossing localized structural boundaries, thereby preserving physically authentic strain jumps. Method verification was conducted based on a real physical experiment: uniaxial compression of a foam concrete specimen equipped with a high-contrast speckle pattern, recorded in 4K resolution at 60 frames per second. The analysis demonstrated that the SA-DIC algorithm reduces the baseline instrumental noise floor by 19.3 % (verified via a Zero-Strain Test on stationary frames). During the active compression phase and macro-crack opening, the application of the SA-DIC method successfully reduced the level of fictitious strains within the intact matrix of the foam concrete by 25.1 % compared to the standard averaging protocol.

Materials science forumVol. 1201
Lutsk National Technical University (UA)
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon