Skin-Contact Electrodes for ECG, Surface EMG, and EEG: A Framework for Evaluation and Reporting

Conventional and soft skin-contact electrodes are difficult to compare when material, interface, and physiological evidence are conflated. This article presents a methodological synthesis and proposed evaluation framework; no new experiments or participant-level data analyses are reported. For non-invasive electrocardiography (ECG), surface electromyography (EMG), and electroencephalography (EEG), it links intended-use claims to applicable tests, measurement definitions, evidence requirements, reporting, and justified conclusions. A common core and conditional modules organize electrical, mechanical, physiological, and wearer assessments. The 36-item Bioelectronic Electrode Evaluation and Reporting (BEER) checklist documents these decisions and missing evidence. A constructed ECG example illustrates the recording-time and event calculations. In that example, two hypothetical configurations each scheduled for 360 s have identical median absolute timing errors of 2 ms among matched beats, but usable scheduled-time coverage is 91.67% (330 s) and 66.67% (240 s). These calculations illustrate why matched-beat timing alone cannot establish full-period monitoring performance. Applications to two published electrode comparisons show how the framework informs the selection of textile ECG electrodes and the interpretation of channel reliability in dry multipin EEG caps. A complete retrospective BEER report for a published printed bioelectronic patch links all 36 checklist dispositions to experimental evidence, reporting gaps and claim-specific conclusions. The framework makes the grounds for supporting, narrowing, or withholding claims explicit; its usability and reproducibility require prospective evaluation.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-11-23
DOI
https://doi.org/10.3390/app162311592
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Skin-Contact Electrodes for ECG, Surface EMG, and EEG: A Framework for Evaluation and Reporting

Manuel Reis Carneiro
Applied Sciences
ECG Monitoring and Analysis
article

Skin-Contact Electrodes for ECG, Surface EMG, and EEG: A Framework for Evaluation and Reporting

Manuel Reis Carneiro
article en

Abstract

Conventional and soft skin-contact electrodes are difficult to compare when material, interface, and physiological evidence are conflated. This article presents a methodological synthesis and proposed evaluation framework; no new experiments or participant-level data analyses are reported. For non-invasive electrocardiography (ECG), surface electromyography (EMG), and electroencephalography (EEG), it links intended-use claims to applicable tests, measurement definitions, evidence requirements, reporting, and justified conclusions. A common core and conditional modules organize electrical, mechanical, physiological, and wearer assessments. The 36-item Bioelectronic Electrode Evaluation and Reporting (BEER) checklist documents these decisions and missing evidence. A constructed ECG example illustrates the recording-time and event calculations. In that example, two hypothetical configurations each scheduled for 360 s have identical median absolute timing errors of 2 ms among matched beats, but usable scheduled-time coverage is 91.67% (330 s) and 66.67% (240 s). These calculations illustrate why matched-beat timing alone cannot establish full-period monitoring performance. Applications to two published electrode comparisons show how the framework informs the selection of textile ECG electrodes and the interpretation of channel reliability in dry multipin EEG caps. A complete retrospective BEER report for a published printed bioelectronic patch links all 36 checklist dispositions to experimental evidence, reporting gaps and claim-specific conclusions. The framework makes the grounds for supporting, narrowing, or withholding claims explicit; its usability and reproducibility require prospective evaluation.

Applied SciencesVol. 16(23)
ETH Zurich (CH)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon