An Interpretable Hybrid TCN–BiGRU Framework with Adaptive Attention for ECG-based Cardiac Abnormality Recognition

Cardiovascular disease (CVD) is among the leading causes of death in the world, and electrocardiogram (ECG) is still the most common non-invasive test employed to assess cardiac abnormalities. Manual ECG interpretation is labour-intensive and prone to inter-observer variability; thus, automated, interpretable ECG classification is warranted. This paper introduces CardioXplainAI, a hybrid, interpretable model consisting of a multi-scale Temporal Convolutional Network (TCN) branch for capturing beat morphology, a bidirectional gated recurrent unit (BiGRU) branch for handling sequential dependencies, and a feature-wise adaptive attention fusion (AAF) module for computing the gate vector to combine the two representations at the sample level. ECG areas related to each prediction are visualised using post-hoc tools, such as Grad-CAM and attention-based saliency. The study is presented as a five-class heartbeat classification task (N, S, V, F, Q) from AAMI EC57. As per a patient-independent 5-fold protocol where all beats of a subject are kept in the same partition, CardioXplainAI obtained an accuracy of 97.89 ± 0.31%, macro-averaged precision, recall and F1-score of 97.52 ± 0.34%, 97.36 ± 0.38% and 97.44 ± 0.35%, respectively, outperforming the directly reproduced 1D-CNN, Bi-LSTM, GRU, CNN-LSTM and TCN baseline models (Holm adjusted p < 0.01). On the general external test set, without fine-tuning, the model achieved 92.64% accuracy on the INCART database (AAMI classes) and 94.72% on a normal-versus-abnormal proxy task from the PTB Diagnostic ECG Database. The model has approximately 0.73 million parameters. The saliency visualisations provide qualitative evidence that the model can highlight diagnostic regions of the ECG (e.g., the QRS complex), but further clinical validation and a prospective evaluation across multiple centres are needed before it can be used in clinics. The implementation is shared openly on the GitHub repository: https://github.com/Sairam-45-hash/CardioXplainAI for reproducibility.

Authors

Institutions

Publication Details

Journal
International Journal of Computational Intelligence Systems
Published
2026-11-23
DOI
https://doi.org/10.1007/s44196-026-01713-1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Interpretable Hybrid TCN–BiGRU Framework with Adaptive Attention for ECG-based Cardiac Abnormality Recognition

Sairam Vallabhuni, N Renuka, Pachala Venkata Naganjaneyulu
International Journal of Computational Intelligence Systems
ECG Monitoring and Analysis
article

An Interpretable Hybrid TCN–BiGRU Framework with Adaptive Attention for ECG-based Cardiac Abnormality Recognition

Sairam Vallabhuni, N Renuka, Pachala Venkata Naganjaneyulu
article en

Abstract

Cardiovascular disease (CVD) is among the leading causes of death in the world, and electrocardiogram (ECG) is still the most common non-invasive test employed to assess cardiac abnormalities. Manual ECG interpretation is labour-intensive and prone to inter-observer variability; thus, automated, interpretable ECG classification is warranted. This paper introduces CardioXplainAI, a hybrid, interpretable model consisting of a multi-scale Temporal Convolutional Network (TCN) branch for capturing beat morphology, a bidirectional gated recurrent unit (BiGRU) branch for handling sequential dependencies, and a feature-wise adaptive attention fusion (AAF) module for computing the gate vector to combine the two representations at the sample level. ECG areas related to each prediction are visualised using post-hoc tools, such as Grad-CAM and attention-based saliency. The study is presented as a five-class heartbeat classification task (N, S, V, F, Q) from AAMI EC57. As per a patient-independent 5-fold protocol where all beats of a subject are kept in the same partition, CardioXplainAI obtained an accuracy of 97.89 ± 0.31%, macro-averaged precision, recall and F1-score of 97.52 ± 0.34%, 97.36 ± 0.38% and 97.44 ± 0.35%, respectively, outperforming the directly reproduced 1D-CNN, Bi-LSTM, GRU, CNN-LSTM and TCN baseline models (Holm adjusted p < 0.01). On the general external test set, without fine-tuning, the model achieved 92.64% accuracy on the INCART database (AAMI classes) and 94.72% on a normal-versus-abnormal proxy task from the PTB Diagnostic ECG Database. The model has approximately 0.73 million parameters. The saliency visualisations provide qualitative evidence that the model can highlight diagnostic regions of the ECG (e.g., the QRS complex), but further clinical validation and a prospective evaluation across multiple centres are needed before it can be used in clinics. The implementation is shared openly on the GitHub repository: https://github.com/Sairam-45-hash/CardioXplainAI for reproducibility.

International Journal of Computational Intelligence Systems
Mizoram University (IN)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon