Evaluation of Early-Age Properties of Portland Cement-Based Systems in the Presence of Accelerating Agents Using Inter-Test Correlations

This study investigates the inter-test correlation between various early-age characteristics of complex cementitious systems. The correlations are used for predicting physical and chemical processes in portland cement–based systems with different chemical and physical accelerators. Correlations were established between the heat of hydration (HoH), ultrasonic pulse velocity (UPV), setting time, compressive strength, and hydrate phases for cement pastes and mortars. When controlling for accelerator type/dosage, temperature, or water-to-cement ratio, correlating HoH to UPV for cement pastes demonstrated R2 values >0.90, indicating reliability when controlled. However, when testing on mortar samples, a reduction in R2 to 0.75 was observed, marking the principal limitation of correlating these two tests. Predicting compressive strength based on HoH when controlling for the water-to-cement ratio or temperature resulted in correlations of R2 = 0.81 and R2 = 0.86, respectively. The main limitation was again when switching to mortar samples, which demonstrated an R2 of 0.66 at sand-to-cement ratio (S/C) = 1.5.

Authors

Institutions

Publication Details

Journal
Journal of Testing and Evaluation
Published
2026-11-25
DOI
https://doi.org/10.1520/jte20250356
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of Early-Age Properties of Portland Cement-Based Systems in the Presence of Accelerating Agents Using Inter-Test Correlations

Prasada Rao Rangaraju, Adam Biehl, James Roberts, Abdul Basit Peerzada
Journal of Testing and Evaluation
Concrete and Cement Materials Research
article

Evaluation of Early-Age Properties of Portland Cement-Based Systems in the Presence of Accelerating Agents Using Inter-Test Correlations

Prasada Rao Rangaraju, Adam Biehl, James Roberts, Abdul Basit Peerzada
article en

Abstract

This study investigates the inter-test correlation between various early-age characteristics of complex cementitious systems. The correlations are used for predicting physical and chemical processes in portland cement–based systems with different chemical and physical accelerators. Correlations were established between the heat of hydration (HoH), ultrasonic pulse velocity (UPV), setting time, compressive strength, and hydrate phases for cement pastes and mortars. When controlling for accelerator type/dosage, temperature, or water-to-cement ratio, correlating HoH to UPV for cement pastes demonstrated R2 values >0.90, indicating reliability when controlled. However, when testing on mortar samples, a reduction in R2 to 0.75 was observed, marking the principal limitation of correlating these two tests. Predicting compressive strength based on HoH when controlling for the water-to-cement ratio or temperature resulted in correlations of R2 = 0.81 and R2 = 0.86, respectively. The main limitation was again when switching to mortar samples, which demonstrated an R2 of 0.66 at sand-to-cement ratio (S/C) = 1.5.

Journal of Testing and Evaluation
Clemson University (US)
South Carolina Department of Transportation, Portland Cement Association Education Foundation
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon