Coupled thermo-mechanical modelling of pantograph contact strip under aerodynamic excitation and interfacial energy dissipation

Tunnel-induced aerodynamic disturbances modify pantograph–catenary interaction and convective heat transfer; however, the resulting cross-field effects on contact-strip temperature and stress remain insufficiently quantified. To quantify these effects, an aerodynamic–dynamic–thermo-mechanical model is developed for open-line and tunnel conditions, in which measured open-line aerodynamic loads and CFD tunnel loads are incorporated into the dynamic model to resolve the transient contact response. A load-to-energy mapping method converts contact force, relative sliding velocity and electrical contact conditions into time-dependent interfacial heat flux and normal pressure. The validity of the model is confirmed through comparison with experimental and reference results. The results show that current, operating speed and material properties affect the contact-strip response through different processes. Increasing current raises Joule heat generation, whereas increasing speed enhances forced convection and reduces local heat accumulation. Material properties affect hotspot development through thermal diffusivity and elastic response, with limited influence on the mean temperature. Relative to open-line operation, the mean contact strip stress increases from 23.27 to 24.45 MPa at 200 km/h and from 52.12 to 53.93 MPa at 250 km/h, corresponding to increments of 1.18 MPa (5.07%) and 1.81 MPa (3.47%), respectively. Increasing the static uplift force from 80 to 120 N reduces the mean surface temperature from 149.62 to 96.46 °C and the mean surface-averaged Mises stress from 5.13 to 2.87 MPa. The model establishes the transfer path from aerodynamic loading to contact response, interfacial heat input, temperature evolution and stress, providing a basis for thermal and structural assessment and operating-parameter optimization under tunnel conditions.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-11-23
DOI
https://doi.org/10.1016/j.csite.2026.108708
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Coupled thermo-mechanical modelling of pantograph contact strip under aerodynamic excitation and interfacial energy dissipation

Haifei Wei, Hangyan Jiang, Ning Zhou, Xiang Kan et al.
Case Studies in Thermal Engineering
Electrical Contact Performance and Analysis
article

Coupled thermo-mechanical modelling of pantograph contact strip under aerodynamic excitation and interfacial energy dissipation

Haifei Wei, Hangyan Jiang, Ning Zhou, Xiang Kan, Xingshuai Zhi, Yo'n'g'ming Yao, Weihua Zhang, Yao Cheng
article en

Abstract

Tunnel-induced aerodynamic disturbances modify pantograph–catenary interaction and convective heat transfer; however, the resulting cross-field effects on contact-strip temperature and stress remain insufficiently quantified. To quantify these effects, an aerodynamic–dynamic–thermo-mechanical model is developed for open-line and tunnel conditions, in which measured open-line aerodynamic loads and CFD tunnel loads are incorporated into the dynamic model to resolve the transient contact response. A load-to-energy mapping method converts contact force, relative sliding velocity and electrical contact conditions into time-dependent interfacial heat flux and normal pressure. The validity of the model is confirmed through comparison with experimental and reference results. The results show that current, operating speed and material properties affect the contact-strip response through different processes. Increasing current raises Joule heat generation, whereas increasing speed enhances forced convection and reduces local heat accumulation. Material properties affect hotspot development through thermal diffusivity and elastic response, with limited influence on the mean temperature. Relative to open-line operation, the mean contact strip stress increases from 23.27 to 24.45 MPa at 200 km/h and from 52.12 to 53.93 MPa at 250 km/h, corresponding to increments of 1.18 MPa (5.07%) and 1.81 MPa (3.47%), respectively. Increasing the static uplift force from 80 to 120 N reduces the mean surface temperature from 149.62 to 96.46 °C and the mean surface-averaged Mises stress from 5.13 to 2.87 MPa. The model establishes the transfer path from aerodynamic loading to contact response, interfacial heat input, temperature evolution and stress, providing a basis for thermal and structural assessment and operating-parameter optimization under tunnel conditions.

Case Studies in Thermal EngineeringVol. 88
China Academy of Railway Sciences (CN), Southwest Jiaotong University (CN)
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon