A standardized XRCT protocol for quantitative 3D shape preferred orientation analysis in rocks

Quantifying three-dimensional (3D) mineral shape-preferred orientation (SPO) is important for interpreting deformation, magma flow, sediment transport, and anisotropic rock properties. X-ray computed tomography (XRCT) enables non-destructive measurement of mineral SPO in three dimensions, but few openly documented workflows link data acquisition, image processing, object extraction, and fabric quantification. This Lab Protocol presents an end-to-end XRCT workflow covering data acquisition, volume reconstruction, phase segmentation, grain-parameter extraction, fabric quantification, and projection of the calculated fabric onto the physical sample for oriented sectioning. An expert-calibrated machine-learning procedure returns reproducible, sample-specific loose and strict candidate minimum grain-volume thresholds (Vmin) for review before an operating threshold is adopted. Filtering at the adopted threshold suppresses the low-volume, poorly resolved object population and associated geometric aliasing, improving the robustness of the calculated 3D SPO. The workflow is demonstrated for spinel-bearing ultramafic rocks; application to other systems requires separate calibration and evaluation.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-11-23
DOI
https://doi.org/10.1371/journal.pone.0363434
Primary Topic
Rock Mechanics and Modeling
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A standardized XRCT protocol for quantitative 3D shape preferred orientation analysis in rocks

Patrice Rey, Sinan Özaydın, Vasileios Chatzaras, Matthew Foley et al.
PLoS ONE
Rock Mechanics and Modeling
article

A standardized XRCT protocol for quantitative 3D shape preferred orientation analysis in rocks

Patrice Rey, Sinan Özaydın, Vasileios Chatzaras, Matthew Foley, Puqing Li
article en

Abstract

Quantifying three-dimensional (3D) mineral shape-preferred orientation (SPO) is important for interpreting deformation, magma flow, sediment transport, and anisotropic rock properties. X-ray computed tomography (XRCT) enables non-destructive measurement of mineral SPO in three dimensions, but few openly documented workflows link data acquisition, image processing, object extraction, and fabric quantification. This Lab Protocol presents an end-to-end XRCT workflow covering data acquisition, volume reconstruction, phase segmentation, grain-parameter extraction, fabric quantification, and projection of the calculated fabric onto the physical sample for oriented sectioning. An expert-calibrated machine-learning procedure returns reproducible, sample-specific loose and strict candidate minimum grain-volume thresholds (Vmin) for review before an operating threshold is adopted. Filtering at the adopted threshold suppresses the low-volume, poorly resolved object population and associated geometric aliasing, improving the robustness of the calculated 3D SPO. The workflow is demonstrated for spinel-bearing ultramafic rocks; application to other systems requires separate calibration and evaluation.

PLoS ONEVol. 21(11)
The University of Sydney (AU)
University of Minnesota, University of Sydney
Rock Mechanics and Modeling
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
A standardized XRCT protocol for quantitative 3D shape preferred orientation analysis in rocks — Patrice Rey, Sinan Özaydın, et al. · PLoS ONE (2026) | TGRS Research Map | TGRS