Constraint-aware PI control of residual chlorine in a drinking water distribution network: Data-driven modeling, robustness analysis, and direct EPANET validation

Maintaining a disinfectant residual throughout a drinking water distribution network is a dynamic control problem because transport and reaction processes produce location-dependent gains and delays. This study developed a reproducible, constraint-aware workflow linking independently validated node-specific models with proportional-integral (PI) control, with the contribution lying in the systematic integration and validation framework rather than in a new PI architecture. Two independent multilevel EPANET experiments supplied seven days for identification and five days for external validation at 60 s sampling. For each of 22 nodes, 1,080 autoregressive models with exogenous input were screened using identification data only and frozen before external evaluation. PI-SIMC was compared with setpoint-weighted and Smith-predictor variants under saturation, actuation delay, and anti-windup. The primary robustness analysis comprised 13,200 paired Monte Carlo simulations; a further 4,400 matched-tuning runs isolated the effect of the Smith predictor. The 22 models achieved median external fit of 88.18% and RMSE of 0.0541 mg/L. PI-SIMC achieved median IAE of 0.682 mg·h/L, RMSE of 0.060 mg/L, and 85.4% time within ±0.05 mg/L. Setpoint weighting reduced nominal overshoot from 5.89% to 1.43% for a median IAE cost of 1.6%. With identical PI2 tuning, Smith prediction lowered median IAE at 15 of 22 nodes but increased it at seven, confirming a node-dependent effect. No-retuning direct EPANET validation was expanded to PI-SIMC at all 22 nodes: every case was finite, nondivergent, and unsaturated, with median IAE of 0.203 mg·h/L and median tracking-band time of 98.4%. One-at-a-time variations of ±20% in bulk and wall decay coefficients and ±10% in global demand left all cases finite and unsaturated; the maximum absolute node-level IAE change was 16.6%. These results support PI-SIMC as a transparent common design and direct network-resolved validation as a practical gate for node-specific extensions.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-11-23
DOI
https://doi.org/10.1371/journal.pone.0359379
Primary Topic
Water Systems and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Constraint-aware PI control of residual chlorine in a drinking water distribution network: Data-driven modeling, robustness analysis, and direct EPANET validation

Carlos Robles-Algarín, Carlos Martínez, Andersson Duarte Cárdenas
PLoS ONE
Water Systems and Optimization
article

Constraint-aware PI control of residual chlorine in a drinking water distribution network: Data-driven modeling, robustness analysis, and direct EPANET validation

Carlos Robles-Algarín, Carlos Martínez, Andersson Duarte Cárdenas
article en

Abstract

Maintaining a disinfectant residual throughout a drinking water distribution network is a dynamic control problem because transport and reaction processes produce location-dependent gains and delays. This study developed a reproducible, constraint-aware workflow linking independently validated node-specific models with proportional-integral (PI) control, with the contribution lying in the systematic integration and validation framework rather than in a new PI architecture. Two independent multilevel EPANET experiments supplied seven days for identification and five days for external validation at 60 s sampling. For each of 22 nodes, 1,080 autoregressive models with exogenous input were screened using identification data only and frozen before external evaluation. PI-SIMC was compared with setpoint-weighted and Smith-predictor variants under saturation, actuation delay, and anti-windup. The primary robustness analysis comprised 13,200 paired Monte Carlo simulations; a further 4,400 matched-tuning runs isolated the effect of the Smith predictor. The 22 models achieved median external fit of 88.18% and RMSE of 0.0541 mg/L. PI-SIMC achieved median IAE of 0.682 mg·h/L, RMSE of 0.060 mg/L, and 85.4% time within ±0.05 mg/L. Setpoint weighting reduced nominal overshoot from 5.89% to 1.43% for a median IAE cost of 1.6%. With identical PI2 tuning, Smith prediction lowered median IAE at 15 of 22 nodes but increased it at seven, confirming a node-dependent effect. No-retuning direct EPANET validation was expanded to PI-SIMC at all 22 nodes: every case was finite, nondivergent, and unsaturated, with median IAE of 0.203 mg·h/L and median tracking-band time of 98.4%. One-at-a-time variations of ±20% in bulk and wall decay coefficients and ±10% in global demand left all cases finite and unsaturated; the maximum absolute node-level IAE change was 16.6%. These results support PI-SIMC as a transparent common design and direct network-resolved validation as a practical gate for node-specific extensions.

PLoS ONEVol. 21(11)
Universidad del Magdalena (CO)
Universidad del Magdalena
Water Systems and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon