IDP-EMA: interpretable dual-path monitoring of equipment events and measurement anomalies in meshed transmission networks

Cloud platforms ingest transmission-grid telemetry from supervisory control and data acquisition systems, phasor measurement units, and Internet-of-Things sensors for energy management and outage handling. Reliable monitoring is difficult under cold start because operating history is short, measurements are heterogeneous across voltage levels, anomalies propagate along multiple electrical paths, and equipment events must be distinguished from corrupted telemetry. We propose IDP-EMA, interpretable dual-path monitoring of equipment events and measurement anomalies, which normalizes measurements by nominal bases and pooled empirical quantiles, estimates neighboring-bus linear residuals, and applies a Kirchhoff current-law gate. The dual path routes strong current-law peaks to a data-fault path, while physical faults are ranked among statistical candidates by a score that excludes the current-law channel. In evaluation, physical/data routing on a stream with mixed physical and data events reaches F1 scores of \(0.95\) and \(0.90\) with \(6.7\%\) uncertain events, while single-class samples leave about \(20\) – \(30\%\) uncertain at the same routing ratio. Stale thresholds under a noisier state estimator misroute physical faults as data, so cloud services must refresh thresholds when the estimation pipeline changes. For edge and cloud operation the same dual-path monitor remains closed-form with sub-millisecond online cost. On IEEE 14-, 30-, and 118-bus systems, full score injection top-1 accuracy is about \(0.87\) , \(0.72\) , and \(0.50\) , and residual-based ranking is preferred in deployment. IDP-EMA targets mixed physical and data monitoring under cold start rather than isolated single-bus localization.

Authors

Institutions

Publication Details

Journal
Journal of Cloud Computing Advances Systems and Applications
Published
2026-11-23
DOI
https://doi.org/10.1186/s13677-026-01026-w
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

IDP-EMA: interpretable dual-path monitoring of equipment events and measurement anomalies in meshed transmission networks

Tengxiang Su, Wenqi Linghu, Jiaxiang Lin, Gong Chen et al.
Journal of Cloud Computing Advances Systems and Applications
Power System Optimization and Stability
article

IDP-EMA: interpretable dual-path monitoring of equipment events and measurement anomalies in meshed transmission networks

Tengxiang Su, Wenqi Linghu, Jiaxiang Lin, Gong Chen, Ying He, Ge Zhang
article en

Abstract

Cloud platforms ingest transmission-grid telemetry from supervisory control and data acquisition systems, phasor measurement units, and Internet-of-Things sensors for energy management and outage handling. Reliable monitoring is difficult under cold start because operating history is short, measurements are heterogeneous across voltage levels, anomalies propagate along multiple electrical paths, and equipment events must be distinguished from corrupted telemetry. We propose IDP-EMA, interpretable dual-path monitoring of equipment events and measurement anomalies, which normalizes measurements by nominal bases and pooled empirical quantiles, estimates neighboring-bus linear residuals, and applies a Kirchhoff current-law gate. The dual path routes strong current-law peaks to a data-fault path, while physical faults are ranked among statistical candidates by a score that excludes the current-law channel. In evaluation, physical/data routing on a stream with mixed physical and data events reaches F1 scores of \(0.95\) and \(0.90\) with \(6.7\%\) uncertain events, while single-class samples leave about \(20\) – \(30\%\) uncertain at the same routing ratio. Stale thresholds under a noisier state estimator misroute physical faults as data, so cloud services must refresh thresholds when the estimation pipeline changes. For edge and cloud operation the same dual-path monitor remains closed-form with sub-millisecond online cost. On IEEE 14-, 30-, and 118-bus systems, full score injection top-1 accuracy is about \(0.87\) , \(0.72\) , and \(0.50\) , and residual-based ranking is preferred in deployment. IDP-EMA targets mixed physical and data monitoring under cold start rather than isolated single-bus localization.

Journal of Cloud Computing Advances Systems and Applications
Guangdong University of Technology (CN), Guizhou Electric Power Design and Research Institute (CN)
National Natural Science Foundation of China, China Southern Power Grid
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon