Assessment of low-intensity magnetic temporal interference for subthreshold deep-brain field modulation
Objective: Non-invasive modulation of deep brain regions is limited by the depth–focality trade-off in conventional transcranial magnetic stimulation (TMS) and by current diffusion due to tissue heterogeneity in transcranial electrical stimulation (TES). This study proposes and evaluates low-intensity magnetic temporal interference stimulation (LI-MTI) for generating subthreshold envelope-modulated electric fields at deep brain targets. Approach: Finite-element simulations were performed using a spherical model and five individualized head models. The computational framework included coil-field calculation, temporal-interference synthesis, envelope extraction, individualized coil placement, and spatial-field assessment. LI-MTI was compared with literature-based TMS references in the spherical model and with Figure-8 TMS, Deymed 120BFV, and transcranial temporal interference stimulation (tTIS) in realistic head models. A prototype LI-MTI system was constructed, and measured magnetic-field distributions were compared with simulations. Main results: In the spherical model, LI-MTI achieved 47.3% greater stimulation depth and 56.3% smaller focal area than the reference TMS configuration under modality-specific criteria. Across five realistic head models, LI-MTI increased peak focality index (Peak FI) by median factors of 1.201 and 1.307, and reduced non-target GM + WM field-exceedance volume at 50% target coverage by 17.1% and 27.2% for the left hippocampus and amygdala, respectively. At matched coverage, two-coil LI-MTI was less spatially confined than tTIS, whereas three-coil optimization reduced median hippocampal non-target volume from 103.74 to 67.24 cm³, approaching the tTIS value of 65.41 cm³. Notably, LI-MTI was generally less sensitive to tissue-conductivity perturbations. Significance: LI-MTI provides an additional controllable degree of freedom for shaping deep envelope fields and showed improved focality over the tested single-coil TMS configurations. Multi-coil optimization further narrowed the performance difference from tTIS while retaining lower sensitivity to conductivity uncertainty. These findings establish computational and engineering feasibility under the tested configurations but do not demonstrate neural efficacy, biological safety, or a general intrinsic advantage over TMS or tTIS.
Authors
- Yajie Xu (ORCID: https://orcid.org/0000-0002-6491-7390)
- Xiaolin Huo (ORCID: https://orcid.org/0000-0001-7416-3601)
- Guanghao Zhang (ORCID: https://orcid.org/0000-0002-6445-2271)
- Hua Lin (ORCID: https://orcid.org/0000-0002-7390-4559)
- Peng Yu
- Ting Zhou (ORCID: https://orcid.org/0009-0006-6138-5858)
- Shuya Cao (ORCID: https://orcid.org/0009-0005-8050-6814)
- Jian Zheng
Institutions
- University of Science and Technology of China (CN)
- Capital Medical University (CN)
- Chinese Academy of Sciences (CN)
- Suzhou Institute of Biomedical Engineering and Technology (CN)
- Xuan Wu Hospital of the Capital Medical University (CN)
- Institute of Electrical Engineering (CN)
Publication Details
- Journal
- Journal of Neural Engineering
- Published
- 2026-11-23
- DOI
- https://doi.org/10.1088/1741-2552/aec590
- Primary Topic
- Transcranial Magnetic Stimulation Studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00