Radiographic Fractal Dimension and Implant Stability: An Ex Vivo Study of Implant Design and Osteotomy Preparation

Background and Objectives: Radiographic fractal dimension (FD) describes image-pattern complexity, but its relationship with immediate implant fixation remains uncertain. This study examined FD before osteotomy preparation and after implant placement in an ex vivo bovine-rib cohort. Materials and Methods: This secondary analysis included 80 blocks, with one implant per block, two implant designs, and four complete preparation protocols (n = 10 per combination). FD was calculated from periapical radiographs using 200 × 50-pixel ROIs. Factorial analyses, baseline-adjusted ANCOVA, and exploratory correlations were performed. Intraobserver reliability was assessed on 32 images measured twice. Results: Baseline FD differed among preparation-protocol groups (p = 0.025). Post-placement differences remained after baseline adjustment for design (p = 0.017) and protocol (p = 0.029), without a significant interaction (p = 0.587). No significant effects on ΔFD were detected for design (p = 0.251), protocol (p = 0.237), or interaction (p = 0.230). Weak nominal correlations of post-placement FD with insertion torque (r = 0.263) and ISQ (r = 0.222) did not retain significance after Holm correction; none of the correlations adjusted for experimental grouping was significant. The absolute-agreement, single-measurement ICC was 0.416 (95% CI, 0.077 to 0.667); matched reanalyses were approximately 0.108 FD units lower than the original values. Conclusions: Adjusted post-placement FD differences were not accompanied by significant between-group effects on ΔFD. Limited reliability, unresolved original-to-repeat disagreement and uncertain ROI correspondence constrain interpretation. These exploratory findings do not demonstrate procedure-induced structural changes or validate FD as a predictor of implant stability or osseointegration.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2026-11-23
DOI
https://doi.org/10.3390/medicina62122297
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Radiographic Fractal Dimension and Implant Stability: An Ex Vivo Study of Implant Design and Osteotomy Preparation

Alfonso Jornet-García, José María Montoya-Carralero, Arturo Sánchez‐Pérez, Moya-Villaescusa María José et al.
Medicina
Dental Implant Techniques and Outcomes
article

Radiographic Fractal Dimension and Implant Stability: An Ex Vivo Study of Implant Design and Osteotomy Preparation

Alfonso Jornet-García, José María Montoya-Carralero, Arturo Sánchez‐Pérez, Moya-Villaescusa María José, Almudena Banegas-Cano
article en

Abstract

Background and Objectives: Radiographic fractal dimension (FD) describes image-pattern complexity, but its relationship with immediate implant fixation remains uncertain. This study examined FD before osteotomy preparation and after implant placement in an ex vivo bovine-rib cohort. Materials and Methods: This secondary analysis included 80 blocks, with one implant per block, two implant designs, and four complete preparation protocols (n = 10 per combination). FD was calculated from periapical radiographs using 200 × 50-pixel ROIs. Factorial analyses, baseline-adjusted ANCOVA, and exploratory correlations were performed. Intraobserver reliability was assessed on 32 images measured twice. Results: Baseline FD differed among preparation-protocol groups (p = 0.025). Post-placement differences remained after baseline adjustment for design (p = 0.017) and protocol (p = 0.029), without a significant interaction (p = 0.587). No significant effects on ΔFD were detected for design (p = 0.251), protocol (p = 0.237), or interaction (p = 0.230). Weak nominal correlations of post-placement FD with insertion torque (r = 0.263) and ISQ (r = 0.222) did not retain significance after Holm correction; none of the correlations adjusted for experimental grouping was significant. The absolute-agreement, single-measurement ICC was 0.416 (95% CI, 0.077 to 0.667); matched reanalyses were approximately 0.108 FD units lower than the original values. Conclusions: Adjusted post-placement FD differences were not accompanied by significant between-group effects on ΔFD. Limited reliability, unresolved original-to-repeat disagreement and uncertain ROI correspondence constrain interpretation. These exploratory findings do not demonstrate procedure-induced structural changes or validate FD as a predictor of implant stability or osseointegration.

MedicinaVol. 62(12)
Universidad de Murcia (ES)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon