Acute physiological responses to robotic hip-exoskeleton-resisted walking: a randomized three-condition crossover trial in healthy adults

Lack of time is a common barrier to exercise, motivating strategies that increase physiological demand without extending exercise duration. We examined acute physiological responses to walking with a wearable robotic hip exoskeleton (Bot Fit) that provides resistive hip torque. In this randomized three-condition crossover trial, 40 healthy adults (20 women; aged 20–59 years) completed 20 min of treadmill walking under three conditions in a single visit, separated by rest until heart rate returned to the pre-exercise resting value (median interval, 30 min): continuous walking without Bot Fit (C-NoBF) and with Bot Fit resistance (C-BF) at an individualized moderate-intensity speed (mean 5.4 km/h), and interval walking with Bot Fit resistance (I-BF), alternating 6 km/h with resistance and 4 km/h without resistance. Resistance was adjusted to maintain heart rate (HR) at 64–76% of age-predicted maximum. Surface electromyography (sEMG) of six trunk and lower-limb muscles (% of maximal voluntary contraction, %MVC), HR, and cardiopulmonary gas exchange were measured. The principal outcome was rectus femoris (RF) activation. sEMG data were complete for 36 participants, and heart-rate and gas-exchange data for 29. RF activation was higher with C-BF (12.11 ± 5.58%MVC; mean difference 2.29%MVC, 95% CI 0.79–3.79, P = 0.002, Cohen’s dz = 0.64) and I-BF (11.34 ± 5.16%MVC; 1.52, 95% CI 0.32–2.73, P = 0.010, dz = 0.53) than with C-NoBF (9.82 ± 4.43%MVC). Gastrocnemius medialis activation, HR, and net metabolic cost were also higher in both Bot Fit conditions (all P ≤ 0.016; e.g., C-BF vs. C-NoBF: HR + 11.90 bpm, 95% CI 9.64–14.16, dz = 2.49; net metabolic cost + 3.12 mL · kg⁻ 1 · min⁻ 1 , 95% CI 1.96–4.28, dz = 1.27). Biceps femoris and tibialis anterior activation increased significantly only with I-BF, whereas rectus abdominis and lumbar erector spinae activation did not differ across conditions. No significant group × condition interaction was found for habitual activity level, and no adverse events occurred. Compared with walking without the device, walking with Bot Fit in resistance mode acutely increased RF and gastrocnemius medialis activation, HR, and metabolic cost. Because device mass and wearing-related effects were not isolated from resistance torque, these differences cannot be attributed specifically to resistance torque. Whether repeated use leads to training adaptations requires longitudinal studies. ClinicalTrials.gov, NCT05266170 . Registered 6 February 2022, before recruitment began.

Authors

Institutions

Publication Details

Journal
BMC Sports Science Medicine and Rehabilitation
Published
2026-11-23
DOI
https://doi.org/10.1186/s13102-026-02228-0
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Acute physiological responses to robotic hip-exoskeleton-resisted walking: a randomized three-condition crossover trial in healthy adults

Suhyun Lee, Jinuk Kim, Yun-Hee Kim
BMC Sports Science Medicine and Rehabilitation
Prosthetics and Rehabilitation Robotics
article

Acute physiological responses to robotic hip-exoskeleton-resisted walking: a randomized three-condition crossover trial in healthy adults

Suhyun Lee, Jinuk Kim, Yun-Hee Kim
article en

Abstract

Lack of time is a common barrier to exercise, motivating strategies that increase physiological demand without extending exercise duration. We examined acute physiological responses to walking with a wearable robotic hip exoskeleton (Bot Fit) that provides resistive hip torque. In this randomized three-condition crossover trial, 40 healthy adults (20 women; aged 20–59 years) completed 20 min of treadmill walking under three conditions in a single visit, separated by rest until heart rate returned to the pre-exercise resting value (median interval, 30 min): continuous walking without Bot Fit (C-NoBF) and with Bot Fit resistance (C-BF) at an individualized moderate-intensity speed (mean 5.4 km/h), and interval walking with Bot Fit resistance (I-BF), alternating 6 km/h with resistance and 4 km/h without resistance. Resistance was adjusted to maintain heart rate (HR) at 64–76% of age-predicted maximum. Surface electromyography (sEMG) of six trunk and lower-limb muscles (% of maximal voluntary contraction, %MVC), HR, and cardiopulmonary gas exchange were measured. The principal outcome was rectus femoris (RF) activation. sEMG data were complete for 36 participants, and heart-rate and gas-exchange data for 29. RF activation was higher with C-BF (12.11 ± 5.58%MVC; mean difference 2.29%MVC, 95% CI 0.79–3.79, P = 0.002, Cohen’s dz = 0.64) and I-BF (11.34 ± 5.16%MVC; 1.52, 95% CI 0.32–2.73, P = 0.010, dz = 0.53) than with C-NoBF (9.82 ± 4.43%MVC). Gastrocnemius medialis activation, HR, and net metabolic cost were also higher in both Bot Fit conditions (all P ≤ 0.016; e.g., C-BF vs. C-NoBF: HR + 11.90 bpm, 95% CI 9.64–14.16, dz = 2.49; net metabolic cost + 3.12 mL · kg⁻ 1 · min⁻ 1 , 95% CI 1.96–4.28, dz = 1.27). Biceps femoris and tibialis anterior activation increased significantly only with I-BF, whereas rectus abdominis and lumbar erector spinae activation did not differ across conditions. No significant group × condition interaction was found for habitual activity level, and no adverse events occurred. Compared with walking without the device, walking with Bot Fit in resistance mode acutely increased RF and gastrocnemius medialis activation, HR, and metabolic cost. Because device mass and wearing-related effects were not isolated from resistance torque, these differences cannot be attributed specifically to resistance torque. Whether repeated use leads to training adaptations requires longitudinal studies. ClinicalTrials.gov, NCT05266170 . Registered 6 February 2022, before recruitment began.

BMC Sports Science Medicine and Rehabilitation
Samsung (South Korea) (KR), Kyungwoon University (KR), Sungkyunkwan University (KR)
National Research Foundation of Korea, Ministry of Science and ICT, South Korea, Samsung
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon