Damage evolution and safety assessment of segmental linings in subway tunnels subjected to pile penetration

With the increasing intensity of urban surface construction activities, incidents of subway tunnel lining structures being penetrated by pile foundations and other foreign objects have occurred frequently, posing a serious threat to tunnel structural safety. To address the insufficient attention in existing studies to penetration-induced damage mechanisms and external invisible damage, this study establishes a refined three-dimensional segmental lining model of a subway tunnel based on the LS-DYNA numerical simulation method. By considering different pile sizes and penetration locations, the penetration process and damage evolution characteristics of tunnel segmental linings are systematically investigated. On this basis, a preliminary quantitative evaluation framework for tunnel penetration resistance is proposed, incorporating key indicators such as maximum damage size, damage influence coefficient, impact force response, and structural deformation to characterize the severity and spatial extent of penetration-induced damage. The results indicate that the pile size is positively correlated with the damage extent. As the penetration location moves closer to the haunch of the tunnel, the structural impact resistance increases, while the affected damage region becomes larger. Compared with single segments, segment joints are more susceptible to extensive damage. In addition, a significant amount of invisible cracking exists on the external interface of the tunnel lining, which constitutes a critical weak point for subsequent assessment and rehabilitation. The findings of this study can provide theoretical support and technical references for safety assessment, emergency monitoring, and strengthening rehabilitation of subway tunnels subjected to penetration incidents.

Authors

Institutions

Publication Details

Journal
International Journal of Protective Structures
Published
2026-11-23
DOI
https://doi.org/10.1177/20414196261509329
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Damage evolution and safety assessment of segmental linings in subway tunnels subjected to pile penetration

Jiapei Xu, Yang Li, Junjun Wang, Ziye Han
International Journal of Protective Structures
Geotechnical Engineering and Underground Structures
article

Damage evolution and safety assessment of segmental linings in subway tunnels subjected to pile penetration

Jiapei Xu, Yang Li, Junjun Wang, Ziye Han
article en

Abstract

With the increasing intensity of urban surface construction activities, incidents of subway tunnel lining structures being penetrated by pile foundations and other foreign objects have occurred frequently, posing a serious threat to tunnel structural safety. To address the insufficient attention in existing studies to penetration-induced damage mechanisms and external invisible damage, this study establishes a refined three-dimensional segmental lining model of a subway tunnel based on the LS-DYNA numerical simulation method. By considering different pile sizes and penetration locations, the penetration process and damage evolution characteristics of tunnel segmental linings are systematically investigated. On this basis, a preliminary quantitative evaluation framework for tunnel penetration resistance is proposed, incorporating key indicators such as maximum damage size, damage influence coefficient, impact force response, and structural deformation to characterize the severity and spatial extent of penetration-induced damage. The results indicate that the pile size is positively correlated with the damage extent. As the penetration location moves closer to the haunch of the tunnel, the structural impact resistance increases, while the affected damage region becomes larger. Compared with single segments, segment joints are more susceptible to extensive damage. In addition, a significant amount of invisible cracking exists on the external interface of the tunnel lining, which constitutes a critical weak point for subsequent assessment and rehabilitation. The findings of this study can provide theoretical support and technical references for safety assessment, emergency monitoring, and strengthening rehabilitation of subway tunnels subjected to penetration incidents.

International Journal of Protective Structures
Shanghai Jiao Tong University (CN), Shanghai Fire Research Institute (CN), Wind Power Engineering (Japan) (JP)
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon