Fixed laboratory-axis readout of retained qubit information near a Floquet crossing

Periodic driving can retain initial-state information, but its usefulness depends on the permitted readout. We study local estimation of an initial-state mixture coefficient in a driven spin–boson model. Each independently prepared copy is measured once at a uniformly sampled, recorded delay using one unchanged Pauli axis. Hierarchical equations of motion yield approximately twice the laboratory-x Fisher information at a Floquet-crossing reference as at two spectrum-selected controls. This readout accesses 90.81% of the mean quantum Fisher information and is nearly optimal within constant binary Pauli projections. The reference-to-control advantage persists throughout a 15° input cone within reconstructed numerical maps, but reverses for a known y input. A broader amplitude scan places the reference close to the largest sampled information. Together, these results give a reproducible, input-dependent benchmark that distinguishes information retained in the state from information accessible to a fixed laboratory readout.

Authors

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11672245/v1
Primary Topic
Quantum Information and Cryptography
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Fixed laboratory-axis readout of retained qubit information near a Floquet crossing

Matthias Jakob
Research Square
Quantum Information and Cryptography
preprint

Fixed laboratory-axis readout of retained qubit information near a Floquet crossing

Matthias Jakob
preprint en

Abstract

Periodic driving can retain initial-state information, but its usefulness depends on the permitted readout. We study local estimation of an initial-state mixture coefficient in a driven spin–boson model. Each independently prepared copy is measured once at a uniformly sampled, recorded delay using one unchanged Pauli axis. Hierarchical equations of motion yield approximately twice the laboratory-x Fisher information at a Floquet-crossing reference as at two spectrum-selected controls. This readout accesses 90.81% of the mean quantum Fisher information and is nearly optimal within constant binary Pauli projections. The reference-to-control advantage persists throughout a 15° input cone within reconstructed numerical maps, but reverses for a known y input. A broader amplitude scan places the reference close to the largest sampled information. Together, these results give a reproducible, input-dependent benchmark that distinguishes information retained in the state from information accessible to a fixed laboratory readout.

Research Square
Quantum Information and Cryptography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon