Efficiency, Efficacy, and Energy-Specific Safety of Pulsed Field Versus Thermal Ablation in Paroxysmal Atrial Fibrillation: Insights From Contemporary Randomized Data (the E 3 -PFA Collaboration)

BACKGROUND: Pulsed field ablation (PFA) is an increasingly adopted, minimally thermal modality for the ablation of atrial fibrillation, but its comparative performance versus contemporary thermal ablation strategies remains incompletely defined. We conducted an aggregate-data meta-analysis of contemporary randomized trials to compare procedural performance, safety, and clinical outcomes of PFA versus cryoballoon ablation and radiofrequency ablation in paroxysmal atrial fibrillation. METHODS: A systematic search identified 6 contemporary randomized controlled trials enrolling 2015 patients with paroxysmal atrial fibrillation. Study-level random-effects meta-analyses were performed to compare procedural performance, peri-procedural safety, and atrial arrhythmia recurrence, with predefined subgroup analyses according to thermal ablation modality. RESULTS: PFA was associated with significantly shorter procedure time, left atrial dwell time, and total ablation time than thermal ablation (all P <0.001), whereas fluoroscopy time and anesthetic strategy were comparable between groups. PFA was associated with a significantly lower risk of peri-procedural serious adverse events than thermal ablation (risk ratio, 0.58 [95% CI, 0.35–0.96]; P =0.036). Persistent phrenic nerve palsy and pulmonary vein stenosis occurred exclusively after thermal ablation. Overall, PFA was associated with a lower risk of atrial arrhythmia recurrence than pooled thermal ablation (risk ratio, 0.86 [95% CI, 0.75–0.99]; P =0.03). Subgroup analyses demonstrated a significant reduction in recurrence compared with cryoballoon ablation (risk ratio, 0.80 [95% CI, 0.65–0.97]; P =0.03), whereas outcomes were comparable between PFA and contemporary radiofrequency (risk ratio, 0.93 [95% CI, 0.77–1.13]; P =0.48). CONCLUSIONS: PFA provides greater procedural efficiency, improved peri-procedural safety, and a lower risk of atrial arrhythmia recurrence than pooled thermal ablation in patients with paroxysmal atrial fibrillation. The efficacy advantage was primarily driven by comparisons with cryoballoon ablation, whereas outcomes were comparable between PFA and contemporary RFA.

Authors

Institutions

Publication Details

Journal
Circulation Arrhythmia and Electrophysiology
Published
2026-11-23
DOI
https://doi.org/10.1161/circep.126.015020
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Efficiency, Efficacy, and Energy-Specific Safety of Pulsed Field Versus Thermal Ablation in Paroxysmal Atrial Fibrillation: Insights From Contemporary Randomized Data (the E 3 -PFA Collaboration)

Helmut Pürerfellner, Xiaomeng Yin, Ramin Ebrahimi, 殷跃辉 et al.
Circulation Arrhythmia and Electrophysiology
Atrial Fibrillation Management and Outcomes
article

Efficiency, Efficacy, and Energy-Specific Safety of Pulsed Field Versus Thermal Ablation in Paroxysmal Atrial Fibrillation: Insights From Contemporary Randomized Data (the E 3 -PFA Collaboration)

Helmut Pürerfellner, Xiaomeng Yin, Ramin Ebrahimi, 殷跃辉, Andreas Rillig, Sanjiv M. Narayan, Minglong Chen, Christian G. Meyer, Kars G.E.J. Neven, Márcio Galindo Kiuchi, K. R. Julian Chun, Boris Schmidt, Huimin Chu, Hongde Hu, Serge Bovéda, Mu Qin, Martin Huth Ruwald, Piotr Futyma, Christian-Hendrik H. Heeger, Maura M. Zylla, Hailei Liu, Laura Perrotta, Bart A. Mulder, Xumin Hou, Martin Martinek, Shaojie Chen, Yumei Xue, Rui Zeng, Chenyang Jiang, Kai Zhang, Jingquan Zhong, Xu Liu
article en

Abstract

BACKGROUND: Pulsed field ablation (PFA) is an increasingly adopted, minimally thermal modality for the ablation of atrial fibrillation, but its comparative performance versus contemporary thermal ablation strategies remains incompletely defined. We conducted an aggregate-data meta-analysis of contemporary randomized trials to compare procedural performance, safety, and clinical outcomes of PFA versus cryoballoon ablation and radiofrequency ablation in paroxysmal atrial fibrillation. METHODS: A systematic search identified 6 contemporary randomized controlled trials enrolling 2015 patients with paroxysmal atrial fibrillation. Study-level random-effects meta-analyses were performed to compare procedural performance, peri-procedural safety, and atrial arrhythmia recurrence, with predefined subgroup analyses according to thermal ablation modality. RESULTS: PFA was associated with significantly shorter procedure time, left atrial dwell time, and total ablation time than thermal ablation (all P <0.001), whereas fluoroscopy time and anesthetic strategy were comparable between groups. PFA was associated with a significantly lower risk of peri-procedural serious adverse events than thermal ablation (risk ratio, 0.58 [95% CI, 0.35–0.96]; P =0.036). Persistent phrenic nerve palsy and pulmonary vein stenosis occurred exclusively after thermal ablation. Overall, PFA was associated with a lower risk of atrial arrhythmia recurrence than pooled thermal ablation (risk ratio, 0.86 [95% CI, 0.75–0.99]; P =0.03). Subgroup analyses demonstrated a significant reduction in recurrence compared with cryoballoon ablation (risk ratio, 0.80 [95% CI, 0.65–0.97]; P =0.03), whereas outcomes were comparable between PFA and contemporary radiofrequency (risk ratio, 0.93 [95% CI, 0.77–1.13]; P =0.48). CONCLUSIONS: PFA provides greater procedural efficiency, improved peri-procedural safety, and a lower risk of atrial arrhythmia recurrence than pooled thermal ablation in patients with paroxysmal atrial fibrillation. The efficacy advantage was primarily driven by comparisons with cryoballoon ablation, whereas outcomes were comparable between PFA and contemporary RFA.

Circulation Arrhythmia and Electrophysiology
Goethe University Frankfurt (DE), University Medical Center Groningen (NL), Shandong University (CN), Universität Hamburg (DE), University of Groningen (NL), Dalian Medical University (CN), Heidelberg University (DE), Sichuan University (CN), Universitätsmedizin Greifswald (DE), Royal Perth Hospital (AU), University Hospital Heidelberg (DE), Sir Run Run Shaw Hospital (CN), Shanghai Chest Hospital (CN), Rigshospitalet (DK), Asklepios Klinik Altona (DE), Cardiovascular Center Bethanien (DE), West China Hospital of Sichuan University (CN), Second Affiliated Hospital of Chongqing Medical University (CN), University Medical Center Hamburg-Eppendorf (DE), Azienda Ospedaliero-Universitaria Careggi (IT), German Centre for Cardiovascular Research (DE), Krankenhaus der Elisabethinen (AT), Agaplesion Bethanien Krankenhaus (DE), Stanford Medicine (US), Clinique Pasteur (FR), First Affiliated Hospital of Dalian Medical University (CN), Guangdong Academy of Medical Sciences (CN), Agaplesion Markus Hospital (DE), Alfried Krupp Hospital (DE), Qilu Hospital of Shandong University (CN), Ningbo First Hospital (CN), Stanford Cardiovascular Institute (US), Heinrich Heine University Düsseldorf (DE), Nanjing Medical University (CN), Chongqing Medical University (CN), University of Lübeck (DE), Stanford University (US)
National Institutes of Health
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon