Toward trustworthy ovarian ultrasound frame classification through leakage-aware and calibrated deep learning

Duplicate and visually similar images can inflate performance estimates when they cross dataset partitions, while test-guided calibration and threshold selection can introduce additional optimism. We developed an integrity-controlled workflow for frame-level ovarian ultrasound classification using the public PCOSGen training and test archives. Exact duplicates were identified with SHA-256 hashing, and cross-partition near copies were screened using perceptual hashing followed by correlation verification. The audit identified 347 near-copy train-test pairs and led to the exclusion of 309 contaminated development frames. Development data were partitioned by perceptual-similarity proxy groups. ResNet-18, MobileNetV3-Small and a shared-encoder global-local gated model were trained, calibrated and evaluated without using test labels for model selection, temperature scaling, threshold selection or ensemble weighting. On 1,448 cleaned held-out frames, the validation-weighted ensemble achieved 0.9309 accuracy, 0.9026 balanced accuracy, 0.9682 sensitivity, 0.8370 specificity, 0.8272 Matthews correlation coefficient, 0.9555 area under the receiver-operating-characteristic curve and 0.9765 average precision. Its Brier score was 0.0734. The ensemble improved the validation-selected sensitivity-specificity balance but did not improve discrimination significantly relative to MobileNetV3-Small (paired area-under-the-curve difference − 0.00113, 95% interval − 0.01027 to 0.00813; bootstrap p = 0.78). A quality-only control achieved an area under the curve of 0.8260, indicating residual acquisition-related information. These findings support integrity auditing, locked-test evaluation and calibrated reporting for public ultrasound benchmarks, while limiting interpretation to frame-level classification rather than patient-level diagnosis.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11266008/v1
Primary Topic
Ovarian function and disorders
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Toward trustworthy ovarian ultrasound frame classification through leakage-aware and calibrated deep learning

Kalakotla Arunima, J Bhavana², Uday Chandra S³
Research Square
Ovarian function and disorders
preprint

Toward trustworthy ovarian ultrasound frame classification through leakage-aware and calibrated deep learning

Kalakotla Arunima, J Bhavana², Uday Chandra S³
preprint en

Abstract

Duplicate and visually similar images can inflate performance estimates when they cross dataset partitions, while test-guided calibration and threshold selection can introduce additional optimism. We developed an integrity-controlled workflow for frame-level ovarian ultrasound classification using the public PCOSGen training and test archives. Exact duplicates were identified with SHA-256 hashing, and cross-partition near copies were screened using perceptual hashing followed by correlation verification. The audit identified 347 near-copy train-test pairs and led to the exclusion of 309 contaminated development frames. Development data were partitioned by perceptual-similarity proxy groups. ResNet-18, MobileNetV3-Small and a shared-encoder global-local gated model were trained, calibrated and evaluated without using test labels for model selection, temperature scaling, threshold selection or ensemble weighting. On 1,448 cleaned held-out frames, the validation-weighted ensemble achieved 0.9309 accuracy, 0.9026 balanced accuracy, 0.9682 sensitivity, 0.8370 specificity, 0.8272 Matthews correlation coefficient, 0.9555 area under the receiver-operating-characteristic curve and 0.9765 average precision. Its Brier score was 0.0734. The ensemble improved the validation-selected sensitivity-specificity balance but did not improve discrimination significantly relative to MobileNetV3-Small (paired area-under-the-curve difference − 0.00113, 95% interval − 0.01027 to 0.00813; bootstrap p = 0.78). A quality-only control achieved an area under the curve of 0.8260, indicating residual acquisition-related information. These findings support integrity auditing, locked-test evaluation and calibrated reporting for public ultrasound benchmarks, while limiting interpretation to frame-level classification rather than patient-level diagnosis.

Research Square
SR University (IN)
Ovarian function and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Toward trustworthy ovarian ultrasound frame classification through leakage-aware and calibrated deep learning — Kalakotla Arunima, J Bhavana², et al. · Research Square (2026) | TGRS Research Map | TGRS