Validation of an X-ray diffraction method for the identification and semi-quantitative determination of quartz in mineral samples according to ISO/IEC 17025:2017

An X-ray diffraction (XRD) procedure using Rietveld refinement was assessed for quartz identification and semi-quantitative determination in mineral samples within an ISO/IEC 17025:2017 validation framework. Quartz abundances were expressed as mass fractions normalized to the modeled crystalline assemblage. Performance was evaluated using independently prepared quartz-fortified ZnO samples, the multiphase reference material AMIS 559, and natural samples. Sample preparation was characterized by sieving and scanning electron microscopy. At approximately 1 wt% quartz, twelve independent preparations yielded a mean apparent recovery of 104.4% and a coefficient of variation of 7.45%. The non-zero apparent quartz response in ZnO blanks limited conclusions regarding low-level trueness and confirmation of the quantification limit. Intermediate-precision coefficients of variation were 7.7%, 1.4%, and 0.1% at approximately 1, 65, and 99 wt% quartz, respectively. High-level precision and preparation comparisons were interpreted within the constraints imposed by phase normalization. Comparison with the indicative quartz value reported for AMIS 559 yielded a mean apparent recovery of 91.0%. Quartz–muscovite peak overlap highlighted the importance of including relevant phases in the refinement model. An uncertainty model combining level-specific intermediate precision, shared recovery-related contributions, and a rectangular allowance for the accepted mean-recovery interval yielded relative expanded estimates of 19.72%, 12.67%, and 12.34% (k = 2). These estimates apply under the stated model assumptions and evaluated conditions. The study provides an experimentally grounded framework for documenting analytical performance and interpreting routine semi-quantitative quartz results in geological laboratories.

Authors

Institutions

Publication Details

Journal
Discover Geoscience
Published
2026-11-23
DOI
https://doi.org/10.1007/s44288-026-00844-4
Primary Topic
X-ray Diffraction in Crystallography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Validation of an X-ray diffraction method for the identification and semi-quantitative determination of quartz in mineral samples according to ISO/IEC 17025:2017

Francisco Iturra, D. Diego Barona, V. Michelle Mármol
Discover Geoscience
X-ray Diffraction in Crystallography
article

Validation of an X-ray diffraction method for the identification and semi-quantitative determination of quartz in mineral samples according to ISO/IEC 17025:2017

Francisco Iturra, D. Diego Barona, V. Michelle Mármol
article en

Abstract

An X-ray diffraction (XRD) procedure using Rietveld refinement was assessed for quartz identification and semi-quantitative determination in mineral samples within an ISO/IEC 17025:2017 validation framework. Quartz abundances were expressed as mass fractions normalized to the modeled crystalline assemblage. Performance was evaluated using independently prepared quartz-fortified ZnO samples, the multiphase reference material AMIS 559, and natural samples. Sample preparation was characterized by sieving and scanning electron microscopy. At approximately 1 wt% quartz, twelve independent preparations yielded a mean apparent recovery of 104.4% and a coefficient of variation of 7.45%. The non-zero apparent quartz response in ZnO blanks limited conclusions regarding low-level trueness and confirmation of the quantification limit. Intermediate-precision coefficients of variation were 7.7%, 1.4%, and 0.1% at approximately 1, 65, and 99 wt% quartz, respectively. High-level precision and preparation comparisons were interpreted within the constraints imposed by phase normalization. Comparison with the indicative quartz value reported for AMIS 559 yielded a mean apparent recovery of 91.0%. Quartz–muscovite peak overlap highlighted the importance of including relevant phases in the refinement model. An uncertainty model combining level-specific intermediate precision, shared recovery-related contributions, and a rectangular allowance for the accepted mean-recovery interval yielded relative expanded estimates of 19.72%, 12.67%, and 12.34% (k = 2). These estimates apply under the stated model assumptions and evaluated conditions. The study provides an experimentally grounded framework for documenting analytical performance and interpreting routine semi-quantitative quartz results in geological laboratories.

Discover GeoscienceVol. 4(1)
Instituto de Investigación Geológico y Energético (EC)
X-ray Diffraction in Crystallography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Validation of an X-ray diffraction method for the identification and semi-quantitative determination of quartz in mineral samples according to ISO/IEC 17025:2017 — Francisco Iturra, D. Diego Barona, et al. · Discover Geoscience (2026) | TGRS Research Map | TGRS