Enhanced Low-Order Harmonic Suppression by Odd-Harmonic Repetitive Control with Reduced Passive Damping for Shipboard Grid-Supply Inverters

Shipboard grid-supply inverters operating at low switching frequencies must suppress rectifier-load harmonics while limiting LC resonance and capacitor-branch loss. This study separates the magnitude, harmonic-parity and phase roles in a fixed 50 Hz LC-filtered inverter. An internal-model comparison establishes an even-centered detuning interval in which odd-harmonic repetitive control has lower magnitude than conventional repetitive control. A gain compensator allocates fifth/seventh-harmonic gain and LC-band attenuation, while an all-pass section provides an independent phase variable. A fully specified numerical reference permits reconstruction of complete closed-loop poles, gain-12/gain-15 responses and parameter checks. Independently tuned multi-resonant and phase-lead repetitive benchmarks expose trade-offs between selected-harmonic rejection and resonance-band sensitivity. Targeted 480/530 Hz detuning and transformer/load-admittance scenarios identify limits to uniform performance advantages. These calculations are distinguished from prototype records acquired with a different baseline implementation. The proposed-controller records at 0.25 ohm report phase-voltage THDs of 2.67, 2.57 and 2.54 percent. Same-resistance hardware records cover four component-comparison configurations and two prior-method comparators, with tuning and measurement boundaries retained. Transient performance is not uniformly superior. The results support a bounded near-even-resonance mechanism and the measured controller–resistor configurations; capacitor-branch loss reduction is not equated with whole-converter efficiency.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-23
DOI
https://doi.org/10.3390/en19235667
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enhanced Low-Order Harmonic Suppression by Odd-Harmonic Repetitive Control with Reduced Passive Damping for Shipboard Grid-Supply Inverters

Zhengkai Lv, Haojun Wu, Ning Wang
Energies
Power Quality and Harmonics
article

Enhanced Low-Order Harmonic Suppression by Odd-Harmonic Repetitive Control with Reduced Passive Damping for Shipboard Grid-Supply Inverters

Zhengkai Lv, Haojun Wu, Ning Wang
article en

Abstract

Shipboard grid-supply inverters operating at low switching frequencies must suppress rectifier-load harmonics while limiting LC resonance and capacitor-branch loss. This study separates the magnitude, harmonic-parity and phase roles in a fixed 50 Hz LC-filtered inverter. An internal-model comparison establishes an even-centered detuning interval in which odd-harmonic repetitive control has lower magnitude than conventional repetitive control. A gain compensator allocates fifth/seventh-harmonic gain and LC-band attenuation, while an all-pass section provides an independent phase variable. A fully specified numerical reference permits reconstruction of complete closed-loop poles, gain-12/gain-15 responses and parameter checks. Independently tuned multi-resonant and phase-lead repetitive benchmarks expose trade-offs between selected-harmonic rejection and resonance-band sensitivity. Targeted 480/530 Hz detuning and transformer/load-admittance scenarios identify limits to uniform performance advantages. These calculations are distinguished from prototype records acquired with a different baseline implementation. The proposed-controller records at 0.25 ohm report phase-voltage THDs of 2.67, 2.57 and 2.54 percent. Same-resistance hardware records cover four component-comparison configurations and two prior-method comparators, with tuning and measurement boundaries retained. Transient performance is not uniformly superior. The results support a bounded near-even-resonance mechanism and the measured controller–resistor configurations; capacitor-branch loss reduction is not equated with whole-converter efficiency.

EnergiesVol. 19(23)
Dalian Maritime University (CN)
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon