Braided fully covered metal stents are associated with a higher risk of stent migration than plastic stents after endoscopic ultrasound-guided hepaticogastrostomy

Background Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is an established biliary drainage procedure when transpapillary access is difficult; however, stent migration can occur. This study compared stent migration between plastic stents (PS) and fully covered self-expandable metal stents (FCSEMS) after EUS-HGS. Methods This single-center retrospective cohort study included patients who underwent initial EUS-HGS with PS alone or FCSEMS alone between July 2014 and March 2025. The primary endpoint was stent migration. Secondary endpoints included technical and clinical success, recurrent biliary obstruction (RBO), time to RBO (TRBO), adverse events, and factors associated with migration. Results Of 116 patients, 107 were analyzed: 48 in the PS group and 59 in the FCSEMS group. All FCSEMS were braided-type stents. Technical success (95.8% vs. 98.3%, P = 0.586) and clinical success (95.7% vs. 94.8%, P = 1.000) were comparable. Adverse event rates did not differ significantly between the groups. Stent migration was significantly more frequent in the FCSEMS group than in the PS group (34.5% vs. 4.3%, P < 0.001), whereas stent occlusion was less frequent (1.7% vs. 15.2%, P = 0.021). TRBO did not differ significantly (179 vs. 106 days; hazard ratio [HR], 1.78; 95% confidence interval [CI], 0.81–3.89; P = 0.142). Multivariate analysis identified FCSEMS placement as a factor associated with stent migration (HR, 8.52; 95% CI, 1.98–36.71; P = 0.004). Conclusions Braided-type FCSEMS were associated with a significantly higher risk of stent migration than PS after EUS-HGS. Therefore, the increased risk of stent migration should be carefully considered when selecting braided-type FCSEMS.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11670735/v1
Primary Topic
Gallbladder and Bile Duct Disorders
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Braided fully covered metal stents are associated with a higher risk of stent migration than plastic stents after endoscopic ultrasound-guided hepaticogastrostomy

Shin Yagi, Sho Hasegawa, Masato Yoneda, Kensuke Kubota et al.
Research Square
Gallbladder and Bile Duct Disorders
preprint

Braided fully covered metal stents are associated with a higher risk of stent migration than plastic stents after endoscopic ultrasound-guided hepaticogastrostomy

Shin Yagi, Sho Hasegawa, Masato Yoneda, Kensuke Kubota, Tomoki Ogata, Yusuke Kurita, Takeshi Iizuka, 佐藤高光, Yu Honda, Takayuki Oda
preprint en

Abstract

Background Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is an established biliary drainage procedure when transpapillary access is difficult; however, stent migration can occur. This study compared stent migration between plastic stents (PS) and fully covered self-expandable metal stents (FCSEMS) after EUS-HGS. Methods This single-center retrospective cohort study included patients who underwent initial EUS-HGS with PS alone or FCSEMS alone between July 2014 and March 2025. The primary endpoint was stent migration. Secondary endpoints included technical and clinical success, recurrent biliary obstruction (RBO), time to RBO (TRBO), adverse events, and factors associated with migration. Results Of 116 patients, 107 were analyzed: 48 in the PS group and 59 in the FCSEMS group. All FCSEMS were braided-type stents. Technical success (95.8% vs. 98.3%, P = 0.586) and clinical success (95.7% vs. 94.8%, P = 1.000) were comparable. Adverse event rates did not differ significantly between the groups. Stent migration was significantly more frequent in the FCSEMS group than in the PS group (34.5% vs. 4.3%, P < 0.001), whereas stent occlusion was less frequent (1.7% vs. 15.2%, P = 0.021). TRBO did not differ significantly (179 vs. 106 days; hazard ratio [HR], 1.78; 95% confidence interval [CI], 0.81–3.89; P = 0.142). Multivariate analysis identified FCSEMS placement as a factor associated with stent migration (HR, 8.52; 95% CI, 1.98–36.71; P = 0.004). Conclusions Braided-type FCSEMS were associated with a significantly higher risk of stent migration than PS after EUS-HGS. Therefore, the increased risk of stent migration should be carefully considered when selecting braided-type FCSEMS.

Research Square
Yokohama City University Hospital (JP)
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon