System-level optimization of seawater-based water supply and cooling for large-scale green hydrogen and ammonia production under variable renewable operation

As green hydrogen and ammonia projects expand in arid coastal regions, coupled demands for process water (PW) and cooling water (CW) increasingly constrain cooling system (CS) selection and water supply infrastructure sizing. To address this research gap, a transferable methodology for designing and techno-economically evaluating cooling and water supply systems for large-scale seawater-based production is presented. It combines time-resolved renewable power and ammonia production modelling, CS performance models, water treatment plant (WTP) sizing, PW and CW storage simulation, and cost assessment. It is applied to the 1.5 GW Phase 1 Murchison Green Hydrogen Project in Western Australia as a case study, using hourly ERA5 climate data for 2015–2024. The investigated CS options include once-through seawater cooling (OTSC), dry cooling (DC), wet cooling towers (WCT), and adiabatic hybrid coolers (AHC). Storage-based optimization substantially reduced the required peak treatment capacities, lowering WTP capacity by 12.4% (to 273 m 3 /h) for PW and CW capacity by 20.6% (to 1,127 m 3 /h) for WCT, and 63.0% (to 636 m 3 /h) for AHC. These reductions translated directly into lower PW-related capital expenditure, operational expenditure, and levelized cost of water (−8.7%, −4.2%, and − 7.3%, respectively). On an integrated cost basis, WCT achieved the lowest levelized cost of cooling (5.96 USD/MWh th ), below DC (38.0%), AHC (44.7%), and OTSC (73.6%). A simplified cost-allocation sensitivity showed that neglecting water treatment and marine infrastructure requirements can alter the CS ranking. The analysis further indicated that CS and water supply make a non-negligible contribution to the total levelized cost of hydrogen, accounting for 2.0–7.4%.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2026-11-23
DOI
https://doi.org/10.1016/j.apenergy.2026.129271
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

System-level optimization of seawater-based water supply and cooling for large-scale green hydrogen and ammonia production under variable renewable operation

Andreas Augustin, Thomas Wintgens, Amr Omar, Greg L. Leslie et al.
Applied Energy
Hybrid Renewable Energy Systems
article

System-level optimization of seawater-based water supply and cooling for large-scale green hydrogen and ammonia production under variable renewable operation

Andreas Augustin, Thomas Wintgens, Amr Omar, Greg L. Leslie, Weizhi Zhang
article en

Abstract

As green hydrogen and ammonia projects expand in arid coastal regions, coupled demands for process water (PW) and cooling water (CW) increasingly constrain cooling system (CS) selection and water supply infrastructure sizing. To address this research gap, a transferable methodology for designing and techno-economically evaluating cooling and water supply systems for large-scale seawater-based production is presented. It combines time-resolved renewable power and ammonia production modelling, CS performance models, water treatment plant (WTP) sizing, PW and CW storage simulation, and cost assessment. It is applied to the 1.5 GW Phase 1 Murchison Green Hydrogen Project in Western Australia as a case study, using hourly ERA5 climate data for 2015–2024. The investigated CS options include once-through seawater cooling (OTSC), dry cooling (DC), wet cooling towers (WCT), and adiabatic hybrid coolers (AHC). Storage-based optimization substantially reduced the required peak treatment capacities, lowering WTP capacity by 12.4% (to 273 m 3 /h) for PW and CW capacity by 20.6% (to 1,127 m 3 /h) for WCT, and 63.0% (to 636 m 3 /h) for AHC. These reductions translated directly into lower PW-related capital expenditure, operational expenditure, and levelized cost of water (−8.7%, −4.2%, and − 7.3%, respectively). On an integrated cost basis, WCT achieved the lowest levelized cost of cooling (5.96 USD/MWh th ), below DC (38.0%), AHC (44.7%), and OTSC (73.6%). A simplified cost-allocation sensitivity showed that neglecting water treatment and marine infrastructure requirements can alter the CS ranking. The analysis further indicated that CS and water supply make a non-negligible contribution to the total levelized cost of hydrogen, accounting for 2.0–7.4%.

Applied EnergyVol. 428
UNSW Sydney (AU), RWTH Aachen University (DE)
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon