Accuracy and Efficiency of Proprietary Navigation, Haptic, and Optical Robotic Systems: An In Vitro Study

Objectives This study aimed to compare the accuracy and efficiency of three specific proprietary computer‐assisted implant surgery systems representing a dynamic navigation system (DNS), a haptic‐feedback robotic system (HRS), and an optical guided robotic system (ORS). Methods A total of 480 dental implants were placed in 120 mandibular and maxillary models, representing both partially edentulous and completely edentulous conditions. The models were allocated to three proprietary systems representing DNS, HRS, and ORS. Implant platform, apex, and angle deviations were calculated and compared among the three groups. Surgical time was also recorded. A linear mixed‐effects model was used to compare the accuracy and efficiency among these three implant surgery systems. Results Linear mixed‐effects modeling revealed significant differences in performance. For all primary accuracy metrics, including angle, platform, and apex deviations, HRS and ORS demonstrated no statistically significant differences ( p > 0.05); however, both systems demonstrated significantly lower deviations compared to DNS ( p < 0.001). Specifically, deviations for HRS, ORS, and DNS were: (0.95° ± 0.67° vs. 0.85° ± 0.50° vs. 1.37° ± 0.69°) for angle ( p < 0.001); (0.70 ± 0.30 mm vs. 0.65 ± 0.36 mm vs. 1.06 ± 0.44 mm) for platform ( p < 0.001); and (0.76 ± 0.32 mm vs. 0.67 ± 0.38 mm vs. 1.04 ± 0.46 mm) for apex ( p < 0.001), respectively. However, HRS exhibited the shortest pre‐operative (97.7 ± 48.2 s) and placement times (221.0 ± 27.0 s), demonstrating higher efficiency compared to both DNS (269.8 ± 41.7 s; 312.7 ± 49.3 s) and ORS (249.1 ± 56.9 s; 258.0 ± 47.8 s) ( p < 0.001). Conclusions Within the limitations of this in vitro study, all three proprietary systems achieved clinically acceptable accuracy. The tested robotic systems showed lower deviations than the tested DNS, while the HRS demonstrated greater procedural efficiency. These findings are specific to the systems evaluated and should not be generalized to other systems within the same technological categories.

Authors

Institutions

Publication Details

Journal
Clinical Implant Dentistry and Related Research
Published
2026-11-23
DOI
https://doi.org/10.1111/cid.70193
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accuracy and Efficiency of Proprietary Navigation, Haptic, and Optical Robotic Systems: An In Vitro Study

Wenying Wang, Baoxin Tao, Feng Wang, Yiqun Wu et al.
Clinical Implant Dentistry and Related Research
Dental Implant Techniques and Outcomes
article

Accuracy and Efficiency of Proprietary Navigation, Haptic, and Optical Robotic Systems: An In Vitro Study

Wenying Wang, Baoxin Tao, Feng Wang, Yiqun Wu, Yixuan Li, Yihan Shen
article en

Abstract

Objectives This study aimed to compare the accuracy and efficiency of three specific proprietary computer‐assisted implant surgery systems representing a dynamic navigation system (DNS), a haptic‐feedback robotic system (HRS), and an optical guided robotic system (ORS). Methods A total of 480 dental implants were placed in 120 mandibular and maxillary models, representing both partially edentulous and completely edentulous conditions. The models were allocated to three proprietary systems representing DNS, HRS, and ORS. Implant platform, apex, and angle deviations were calculated and compared among the three groups. Surgical time was also recorded. A linear mixed‐effects model was used to compare the accuracy and efficiency among these three implant surgery systems. Results Linear mixed‐effects modeling revealed significant differences in performance. For all primary accuracy metrics, including angle, platform, and apex deviations, HRS and ORS demonstrated no statistically significant differences ( p > 0.05); however, both systems demonstrated significantly lower deviations compared to DNS ( p < 0.001). Specifically, deviations for HRS, ORS, and DNS were: (0.95° ± 0.67° vs. 0.85° ± 0.50° vs. 1.37° ± 0.69°) for angle ( p < 0.001); (0.70 ± 0.30 mm vs. 0.65 ± 0.36 mm vs. 1.06 ± 0.44 mm) for platform ( p < 0.001); and (0.76 ± 0.32 mm vs. 0.67 ± 0.38 mm vs. 1.04 ± 0.46 mm) for apex ( p < 0.001), respectively. However, HRS exhibited the shortest pre‐operative (97.7 ± 48.2 s) and placement times (221.0 ± 27.0 s), demonstrating higher efficiency compared to both DNS (269.8 ± 41.7 s; 312.7 ± 49.3 s) and ORS (249.1 ± 56.9 s; 258.0 ± 47.8 s) ( p < 0.001). Conclusions Within the limitations of this in vitro study, all three proprietary systems achieved clinically acceptable accuracy. The tested robotic systems showed lower deviations than the tested DNS, while the HRS demonstrated greater procedural efficiency. These findings are specific to the systems evaluated and should not be generalized to other systems within the same technological categories.

Clinical Implant Dentistry and Related ResearchVol. 28(6)
Shanghai Jiao Tong University (CN), Shanghai Stomatological Hospital (CN), Shanghai Ninth People's Hospital (CN), University of Hong Kong (HK)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon