Toward translational validation of robot-assisted microvascular anastomosis: lessons from reconstructive microsurgery for cerebrovascular bypass

Background Robot-assisted microsurgical platforms are used clinically in reconstructive and supermicrosurgical procedures, whereas direct robot-assisted intracranial vessel-to-vessel anastomosis has not been reported in a peer-reviewed clinical series. A translational review must therefore distinguish established peripheral experience from preclinical and investigational intracranial evidence. Methods This narrative review searched PubMed/MEDLINE and Google Scholar, supplemented by reference-list screening, ClinicalTrials.gov , and US Food and Drug Administration records, through August 1, 2026. Human clinical, biological preclinical, cadaveric, bench, simulation, regulatory, and trial evidence was classified by translational tier. Reporting was informed by SANRA, and the review explicitly documented eligibility, source provenance, overlapping cohorts, and the distinction between primary-study results and published evidence syntheses. Results Human evidence is concentrated in lymphaticovenous anastomosis and free-flap reconstruction. Small prospective studies and case series support technical feasibility and high immediate patency or short-term flap survival, but robot-assisted anastomoses are generally slower during early adoption and comparative long-term data remain sparse. A single-arm 2026 meta-analysis reported pooled flap survival of 96% and a mean anastomosis time of 39.1 min, but these estimates reflect heterogeneous, mainly uncontrolled reports and do not establish superiority. In the 20-participant MUSA pilot follow-up, patency among assessed anastomoses was 76.5% overall (66.6% robot-assisted versus 81.8% manual); the study was not powered for comparative efficacy. Intracranial evidence consists of bench and dynamic models, two cadaveric bypass reports, and a non-peer-reviewed institutional report of three investigational robot-assisted encephaloduroarteriosynangiosis procedures. Encephaloduroarteriosynangiosis is an indirect bypass. No peer-reviewed procedural, safety, patency, endothelial, imaging, or neurological outcome data were available for these cases by the search cutoff. Conclusion Robot-assisted anastomosis is technically feasible in selected reconstructive settings, but direct intracranial bypass remains preclinical. Evidence generated with different robotic platforms is not interchangeable. Translation should follow an IDEAL-D-aligned pathway with staged testing of corridor access, target-motion tolerance, tissue force, temporary occlusion, patency, endothelial injury, conversion, team performance, and resource requirements before any direct first-in-human series.

Authors

Institutions

Publication Details

Journal
Frontiers in Neurology
Published
2026-11-23
DOI
https://doi.org/10.3389/fneur.2026.1962392
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Toward translational validation of robot-assisted microvascular anastomosis: lessons from reconstructive microsurgery for cerebrovascular bypass

Zhen Li, Xin Su, Ma Yongjie, Ao Qin et al.
Frontiers in Neurology
Reconstructive Surgery and Microvascular Techniques
article

Toward translational validation of robot-assisted microvascular anastomosis: lessons from reconstructive microsurgery for cerebrovascular bypass

Zhen Li, Xin Su, Ma Yongjie, Ao Qin, Liyong Sun, Hongqi Zhang
article en

Abstract

Background Robot-assisted microsurgical platforms are used clinically in reconstructive and supermicrosurgical procedures, whereas direct robot-assisted intracranial vessel-to-vessel anastomosis has not been reported in a peer-reviewed clinical series. A translational review must therefore distinguish established peripheral experience from preclinical and investigational intracranial evidence. Methods This narrative review searched PubMed/MEDLINE and Google Scholar, supplemented by reference-list screening, ClinicalTrials.gov , and US Food and Drug Administration records, through August 1, 2026. Human clinical, biological preclinical, cadaveric, bench, simulation, regulatory, and trial evidence was classified by translational tier. Reporting was informed by SANRA, and the review explicitly documented eligibility, source provenance, overlapping cohorts, and the distinction between primary-study results and published evidence syntheses. Results Human evidence is concentrated in lymphaticovenous anastomosis and free-flap reconstruction. Small prospective studies and case series support technical feasibility and high immediate patency or short-term flap survival, but robot-assisted anastomoses are generally slower during early adoption and comparative long-term data remain sparse. A single-arm 2026 meta-analysis reported pooled flap survival of 96% and a mean anastomosis time of 39.1 min, but these estimates reflect heterogeneous, mainly uncontrolled reports and do not establish superiority. In the 20-participant MUSA pilot follow-up, patency among assessed anastomoses was 76.5% overall (66.6% robot-assisted versus 81.8% manual); the study was not powered for comparative efficacy. Intracranial evidence consists of bench and dynamic models, two cadaveric bypass reports, and a non-peer-reviewed institutional report of three investigational robot-assisted encephaloduroarteriosynangiosis procedures. Encephaloduroarteriosynangiosis is an indirect bypass. No peer-reviewed procedural, safety, patency, endothelial, imaging, or neurological outcome data were available for these cases by the search cutoff. Conclusion Robot-assisted anastomosis is technically feasible in selected reconstructive settings, but direct intracranial bypass remains preclinical. Evidence generated with different robotic platforms is not interchangeable. Translation should follow an IDEAL-D-aligned pathway with staged testing of corridor access, target-motion tolerance, tissue force, temporary occlusion, patency, endothelial injury, conversion, team performance, and resource requirements before any direct first-in-human series.

Frontiers in NeurologyVol. 17
Capital Medical University (CN), Chinese Academy of Sciences (CN), Xuan Wu Hospital of the Capital Medical University (CN), Institute of Automation (CN)
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon