Label-Free Detection of MUC1 Using Reduced Graphene Oxide/PEDOT:PSS/Glutaraldehyde-Based Resistive Biosensor

Mucin 1 (MUC1), a transmembrane glycoprotein that is present in the luminal surface of healthy epithelial cells, acts as an oncomarker for multiple cancers, including breast and ovary. This work reports the development of a label-free, easy-to-use, and resistive biosensor for the quantitative detection of MUC1 in serum samples. The sensor utilized poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) and glutaraldehyde (GA)-functionalized reduced graphene oxide (RGO) as the transducer layer and monoclonal MUC1 antibodies as the receptor of the target protein. The successful integration of the sensor’s components was verified using electron microscopy, UV-visible spectroscopy, and Fourier transform infrared spectroscopy. The RGO/PEDOT:PSS/GA/mAb sensors were found to exhibit excellent and reproducible responses ranging from 2.68% to 38.65% for 0.1–100 ng/mL MUC1, with p < 0.0001. The sensors also demonstrated high selectivity for MUC1 against non-target biomolecules, including SPINK1, PSA, CA125, and fetal bovine serum, showing minimal cross-reactivity toward these. Furthermore, the RGO/PEDOT:PSS/GA/mAb sensor was evaluated using 12 clinical serum samples representing different ovarian pathological conditions, including serous cystadenoma, simple cyst, ovarian cyst with torsion, mature cystic teratoma, surface epithelial tumor, and high-grade adenocarcinoma. The preliminary evaluation of the clinical samples using the sensors resulted in measurable responses across the tested pathological categories. However, substantial inter-sample variability and overlap among the tested cohorts indicated limited diagnostic discrimination capabilities of MUC1. The sensor responses obtained for the clinical specimens were further validated with enzyme-linked immunosorbent assay (ELISA) measurements and were found to be in agreement. It is believed that this work may lead to development of portable, handheld devices for detection of MUC1, which can play an important role in the rapid diagnosis of multiple ovarian conditions in a simple way.

Authors

Institutions

Publication Details

Journal
ACS Applied Electronic Materials
Published
2026-11-23
DOI
https://doi.org/10.1021/acsaelm.6c01715
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Label-Free Detection of MUC1 Using Reduced Graphene Oxide/PEDOT:PSS/Glutaraldehyde-Based Resistive Biosensor

Sudhanshu Kumar Shukla, Ruma Ghosh, Sunita S. Vernekar, Bolivia Konthoujam et al.
ACS Applied Electronic Materials
Electrochemical sensors and biosensors
article

Label-Free Detection of MUC1 Using Reduced Graphene Oxide/PEDOT:PSS/Glutaraldehyde-Based Resistive Biosensor

Sudhanshu Kumar Shukla, Ruma Ghosh, Sunita S. Vernekar, Bolivia Konthoujam, Purushotham Reddy
article en

Abstract

Mucin 1 (MUC1), a transmembrane glycoprotein that is present in the luminal surface of healthy epithelial cells, acts as an oncomarker for multiple cancers, including breast and ovary. This work reports the development of a label-free, easy-to-use, and resistive biosensor for the quantitative detection of MUC1 in serum samples. The sensor utilized poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) and glutaraldehyde (GA)-functionalized reduced graphene oxide (RGO) as the transducer layer and monoclonal MUC1 antibodies as the receptor of the target protein. The successful integration of the sensor’s components was verified using electron microscopy, UV-visible spectroscopy, and Fourier transform infrared spectroscopy. The RGO/PEDOT:PSS/GA/mAb sensors were found to exhibit excellent and reproducible responses ranging from 2.68% to 38.65% for 0.1–100 ng/mL MUC1, with p < 0.0001. The sensors also demonstrated high selectivity for MUC1 against non-target biomolecules, including SPINK1, PSA, CA125, and fetal bovine serum, showing minimal cross-reactivity toward these. Furthermore, the RGO/PEDOT:PSS/GA/mAb sensor was evaluated using 12 clinical serum samples representing different ovarian pathological conditions, including serous cystadenoma, simple cyst, ovarian cyst with torsion, mature cystic teratoma, surface epithelial tumor, and high-grade adenocarcinoma. The preliminary evaluation of the clinical samples using the sensors resulted in measurable responses across the tested pathological categories. However, substantial inter-sample variability and overlap among the tested cohorts indicated limited diagnostic discrimination capabilities of MUC1. The sensor responses obtained for the clinical specimens were further validated with enzyme-linked immunosorbent assay (ELISA) measurements and were found to be in agreement. It is believed that this work may lead to development of portable, handheld devices for detection of MUC1, which can play an important role in the rapid diagnosis of multiple ovarian conditions in a simple way.

ACS Applied Electronic Materials
Indian Institute of Technology Dharwad (IN), Karnataka Institute of Medical Sciences (IN)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon