Energy LossesAlong Broad Crested Weir Within a Large Circular Open Channel
In this experimental investigation some geometrical characteristics and the determination of the energy losses, from the water flow over a broad crested weir within a large circular (D) open channel, are presented, analyzed and discussed. The diameter D=const., while the lengths L of the weir and the upstream hydraulic heads h are varying. The one-dimensional equations are presented and the dimensionless energy losses, ΔΗ/Η1, from the flow over the weir are calculated – based on laboratory experiments. The dimensionless critical flow depths yc over the weir’s crest are related to dimensionless distances (Lc) from the weir’s brink, while the dimensionless downstream (beyond the weir) depth is also investigated and two relative equations are proposed. ΔΗ/Η1 is related to the ratios h/L and L/D and a dimensionless equation is provided. The authors believe that the present results may help the hydraulic engineer when designing pertinent hydraulic structures.
Authors
- Retsinis Eugene
- Demetriou John
Institutions
- National Technical University of Athens (GR)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-23
- DOI
- https://doi.org/10.5281/zenodo.24457301
- Primary Topic
- Hydraulic flow and structures
- Type
- article
- Field-Weighted Citation Impact
- 0.00