Ex Vivo Genetic Silencing of Donor MHC via Normothermic Machine Perfusion and Prolonged Survival of Kidney Allograft

Background: Donor major histocompatibility complex (MHC) antigens trigger vigorous immune responses following transplantation, leading to allograft rejection. While recipient-targeted immunosuppression remains the mainstay of clinical practice, therapeutic interventions directed at donor organs are limited. We investigated whether ex vivo gene silencing of donor beta-2 microglobulin ( B2m ) and major histocompatibility complex class II transactivator ( Ciita ) delivered during normothermic machine perfusion could reduce graft immunogenicity, attenuate acute rejection, extend allograft survival, and overcome pre-existing host anti-vector immunity. Methods: In this study, we employed normothermic machine perfusion to deliver lentiviral vectors targeting B2m (sh B2m ) and Ciita (sh Ciita ) for ex vivo gene silencing specifically on donor kidneys, with the aim of silencing MHC molecules to reduce immunogenicity and enhance immunocompatibility using a fully MHC-mismatched rat model (BN to Lewis). Graft modification was evaluated either without immunosuppression or combined with a short-term of immunosuppression. Vector transduction efficiency, biodistribution, donor MHC expression, histopathology, immune cell infiltration, donor-specific antibody production, and longitudinal graft function were systematically assessed. A pre-immunized recipient model was established via subcutaneous vector administration prior to transplantation to evaluate the impact of pre-existing anti-vector humoral immunity. Results: Ex vivo normothermic machine perfusion restricted vector delivery to donor kidneys without off-target organ integration. On postoperative day 5, dual silencing significantly downregulated donor MHC class I and class II expression, attenuated tissue injury, and inhibited immune cell infiltration. Gene silencing blunted donor-specific IgM production and reduced effector CD4 + IFN-γ + T cells. Combined with short-course immunosuppression, dual silencing achieved a 75% prolonged allograft survival rate compared with cold storage and machine perfusion controls, with stable long-term graft function. Pre-existing host anti-vector immunity did not compromise efficacy, yielding a comparable 63% prolonged survival rate. Conclusions: Ex vivo donor B2m and Ciita silencing during normothermic machine perfusion combined with transient immunosuppression attenuated acute rejection, prolonged kidney allograft survival, and bypassed host pre-existing anti-vector immunity.

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2026-11-23
DOI
https://doi.org/10.1681/asn.0000001312
Primary Topic
Renal Transplantation Outcomes and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Ex Vivo Genetic Silencing of Donor MHC via Normothermic Machine Perfusion and Prolonged Survival of Kidney Allograft

Jiang Qiu, Xiaomeng Zheng, 陈海薇, Tong Chen et al.
Journal of the American Society of Nephrology
Renal Transplantation Outcomes and Treatments
article

Ex Vivo Genetic Silencing of Donor MHC via Normothermic Machine Perfusion and Prolonged Survival of Kidney Allograft

Jiang Qiu, Xiaomeng Zheng, 陈海薇, Tong Chen, Shicong Yang, Liang Tao, Xiaoshun He, Yizhong Tu, Kaixin Lan, Yunliang Xie, Qin Wang, Shuangjin Yu, Li Lin, Peiye Wang
article en

Abstract

Background: Donor major histocompatibility complex (MHC) antigens trigger vigorous immune responses following transplantation, leading to allograft rejection. While recipient-targeted immunosuppression remains the mainstay of clinical practice, therapeutic interventions directed at donor organs are limited. We investigated whether ex vivo gene silencing of donor beta-2 microglobulin ( B2m ) and major histocompatibility complex class II transactivator ( Ciita ) delivered during normothermic machine perfusion could reduce graft immunogenicity, attenuate acute rejection, extend allograft survival, and overcome pre-existing host anti-vector immunity. Methods: In this study, we employed normothermic machine perfusion to deliver lentiviral vectors targeting B2m (sh B2m ) and Ciita (sh Ciita ) for ex vivo gene silencing specifically on donor kidneys, with the aim of silencing MHC molecules to reduce immunogenicity and enhance immunocompatibility using a fully MHC-mismatched rat model (BN to Lewis). Graft modification was evaluated either without immunosuppression or combined with a short-term of immunosuppression. Vector transduction efficiency, biodistribution, donor MHC expression, histopathology, immune cell infiltration, donor-specific antibody production, and longitudinal graft function were systematically assessed. A pre-immunized recipient model was established via subcutaneous vector administration prior to transplantation to evaluate the impact of pre-existing anti-vector humoral immunity. Results: Ex vivo normothermic machine perfusion restricted vector delivery to donor kidneys without off-target organ integration. On postoperative day 5, dual silencing significantly downregulated donor MHC class I and class II expression, attenuated tissue injury, and inhibited immune cell infiltration. Gene silencing blunted donor-specific IgM production and reduced effector CD4 + IFN-γ + T cells. Combined with short-course immunosuppression, dual silencing achieved a 75% prolonged allograft survival rate compared with cold storage and machine perfusion controls, with stable long-term graft function. Pre-existing host anti-vector immunity did not compromise efficacy, yielding a comparable 63% prolonged survival rate. Conclusions: Ex vivo donor B2m and Ciita silencing during normothermic machine perfusion combined with transient immunosuppression attenuated acute rejection, prolonged kidney allograft survival, and bypassed host pre-existing anti-vector immunity.

Journal of the American Society of Nephrology
Jiangxi University of Water Resources and Electric Power (CN), Nanchang University (CN), Sun Yat-sen University (CN), Key Laboratory of Guangdong Province (CN), First Affiliated Hospital of Xi'an Jiaotong University (CN), The First Affiliated Hospital, Sun Yat-sen University (CN)
Renal Transplantation Outcomes and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon