Push-Out Bond Strength of Customized Fiberglass Posts Luted with Glass Ionomer and Resin-Based Cements: An In Vitro Study

This study evaluated the push-out bond strength of a glass ionomer cement and three resin cements with different adhesion strategies used for luting customized fiberglass posts. Sixty human premolars were endodontically treated and restored with customized fiberglass posts relined with composite resin. The specimens were randomly assigned to four groups (n = 15) according to the luting cement: glass ionomer cement (G), dual-cure resin cement (A), self-adhesive resin cement (U), and self-etch dual-curing resin cement (M). Each root was sectioned into 1-mm-thick slices, and three slices corresponding to the cervical, middle, and apical thirds were selected for push-out bond strength testing using a universal testing machine operating at a crosshead speed of 0.5 mm/min until post displacement occurred. Data distribution was assessed using the Shapiro–Wilk test and found to be approximately normal. A two-way analysis of variance evaluated the effects of cement type and root third. Because Levene's test indicated heterogeneity of variances among the 12 experimental conditions, Games–Howell post hoc tests were used for pairwise comparisons. Statistical significance was set at α = 0.05. Significant effects were observed for cement type (p < 0.001), root third (p = 0.001), and their interaction (p < 0.001). When the same root thirds were compared among the luting cements, group A demonstrated significantly higher push-out bond strength than group G in the middle third (p = 0.025) and higher push-out bond strength than group U in the cervical third (p = 0.009). Bond strength did not differ significantly among cements and were observed in the apical third or among root thirds within the same cement group (p > 0.05). The cementation protocol influenced the push-out bond strength of anatomically customized fiber posts. Conventional adhesive resin cementation provided more favorable bonding performance than self-adhesive resin cement and glass ionomer cement, while bond strength remained generally consistent across root thirds.

Authors

Institutions

Publication Details

Journal
European Journal of Dentistry
Published
2026-11-23
DOI
https://doi.org/10.1055/s-0046-1829083
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Push-Out Bond Strength of Customized Fiberglass Posts Luted with Glass Ionomer and Resin-Based Cements: An In Vitro Study

Lucato-Budziak Mc, Everdan Carneiro, Vânia Portela Ditzel Westphalen, Mário Honorato da Silva e Souza Júnior et al.
European Journal of Dentistry
Dental materials and restorations
article

Push-Out Bond Strength of Customized Fiberglass Posts Luted with Glass Ionomer and Resin-Based Cements: An In Vitro Study

Lucato-Budziak Mc, Everdan Carneiro, Vânia Portela Ditzel Westphalen, Mário Honorato da Silva e Souza Júnior, Rodrigo Nunes Rached, André Luiz da Costa Michelotto, Antônio Batista, Ulisses Xavier da Silva Neto
article en

Abstract

This study evaluated the push-out bond strength of a glass ionomer cement and three resin cements with different adhesion strategies used for luting customized fiberglass posts. Sixty human premolars were endodontically treated and restored with customized fiberglass posts relined with composite resin. The specimens were randomly assigned to four groups (n = 15) according to the luting cement: glass ionomer cement (G), dual-cure resin cement (A), self-adhesive resin cement (U), and self-etch dual-curing resin cement (M). Each root was sectioned into 1-mm-thick slices, and three slices corresponding to the cervical, middle, and apical thirds were selected for push-out bond strength testing using a universal testing machine operating at a crosshead speed of 0.5 mm/min until post displacement occurred. Data distribution was assessed using the Shapiro–Wilk test and found to be approximately normal. A two-way analysis of variance evaluated the effects of cement type and root third. Because Levene's test indicated heterogeneity of variances among the 12 experimental conditions, Games–Howell post hoc tests were used for pairwise comparisons. Statistical significance was set at α = 0.05. Significant effects were observed for cement type (p < 0.001), root third (p = 0.001), and their interaction (p < 0.001). When the same root thirds were compared among the luting cements, group A demonstrated significantly higher push-out bond strength than group G in the middle third (p = 0.025) and higher push-out bond strength than group U in the cervical third (p = 0.009). Bond strength did not differ significantly among cements and were observed in the apical third or among root thirds within the same cement group (p > 0.05). The cementation protocol influenced the push-out bond strength of anatomically customized fiber posts. Conventional adhesive resin cementation provided more favorable bonding performance than self-adhesive resin cement and glass ionomer cement, while bond strength remained generally consistent across root thirds.

European Journal of Dentistry
Pontifícia Universidade Católica do Paraná (BR), Universidade Federal do Paraná (BR)
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon