Optimized Design and Analysis of Steel Pipe Rack for Oil and Gas Industries as Per Indian Standard Codes

Steel pipe racks are essential structural systems in oil and gas facilities, refineries and petrochemical plants. They support process pipelines, utility lines, cable trays and associated services while maintaining organized routing, access and operational continuity. Their design is challenging because the supporting frame is subjected to dead load, pipe operating and test loads, wind, earthquake, thermal effects, maintenance actions and other project-specific forces. The present study evaluates the structural behaviour and preliminary economy of a three-tier steel pipe rack having an overall length of 50 m, width of 6 m and height of 24 m. The adopted longitudinal column spacing is 10 m and the nominal vertical tier spacing is 3 m. The basic wind speed is 47 m/s and the project basis identifies the site as Seismic Zone V. Three structural configurations are compared: a conventional moment-resisting frame, an X-braced frame and an A-type braced frame. The project report provides estimated steel quantities of 115 t, 90 t and 85 t, respectively. The corresponding reported maximum lateral deflections are 42 mm, 29 mm and 23 mm; reported wind base shears are 1,090 kN, 849 kN and 743 kN; and maximum member utilization ratios are 0.90, 0.83 and 0.82. On the basis of these supplied values, the A-type braced alternative has the lowest reported steel quantity, deflection, wind base shear and utilization ratio. Relative to the moment frame, its reported steel quantity is lower by 26.09% and its maximum deflection is lower by 45.24%. The findings indicate that bracing can improve the lateral response and material efficiency of the studied pipe-rack model. The A-type arrangement is therefore identified as the preferred preliminary alternative within the reported comparison. This conclusion is conditional: the source report contains load-input and modelling details that require reconciliation, and the reported values should be verified against the final STAAD.Pro model, code checks, connection design, foundation reactions and piping flexibility requirements before construction or publication as a validated design.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-23
DOI
https://doi.org/10.5281/zenodo.24463517
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimized Design and Analysis of Steel Pipe Rack for Oil and Gas Industries as Per Indian Standard Codes

Abhijeet R. Undre, A. B. Pujari, More Ashish Hemant
Zenodo (CERN European Organization for Nuclear Research)
Structural Load-Bearing Analysis
article

Optimized Design and Analysis of Steel Pipe Rack for Oil and Gas Industries as Per Indian Standard Codes

Abhijeet R. Undre, A. B. Pujari, More Ashish Hemant
article en

Abstract

Steel pipe racks are essential structural systems in oil and gas facilities, refineries and petrochemical plants. They support process pipelines, utility lines, cable trays and associated services while maintaining organized routing, access and operational continuity. Their design is challenging because the supporting frame is subjected to dead load, pipe operating and test loads, wind, earthquake, thermal effects, maintenance actions and other project-specific forces. The present study evaluates the structural behaviour and preliminary economy of a three-tier steel pipe rack having an overall length of 50 m, width of 6 m and height of 24 m. The adopted longitudinal column spacing is 10 m and the nominal vertical tier spacing is 3 m. The basic wind speed is 47 m/s and the project basis identifies the site as Seismic Zone V. Three structural configurations are compared: a conventional moment-resisting frame, an X-braced frame and an A-type braced frame. The project report provides estimated steel quantities of 115 t, 90 t and 85 t, respectively. The corresponding reported maximum lateral deflections are 42 mm, 29 mm and 23 mm; reported wind base shears are 1,090 kN, 849 kN and 743 kN; and maximum member utilization ratios are 0.90, 0.83 and 0.82. On the basis of these supplied values, the A-type braced alternative has the lowest reported steel quantity, deflection, wind base shear and utilization ratio. Relative to the moment frame, its reported steel quantity is lower by 26.09% and its maximum deflection is lower by 45.24%. The findings indicate that bracing can improve the lateral response and material efficiency of the studied pipe-rack model. The A-type arrangement is therefore identified as the preferred preliminary alternative within the reported comparison. This conclusion is conditional: the source report contains load-input and modelling details that require reconciliation, and the reported values should be verified against the final STAAD.Pro model, code checks, connection design, foundation reactions and piping flexibility requirements before construction or publication as a validated design.

Zenodo (CERN European Organization for Nuclear Research)
Savitribai Phule Pune University (IN)
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon