Padlock probe–RCA–Cas12a for cancer liquid biopsy: molecular interface engineering, analytical validation, and clinical translation

Liquid biopsy enables minimally invasive assessment of tumor-derived biomarkers, but reliable early cancer detection and longitudinal monitoring remain challenging because of low target abundance, background nucleic acids, preanalytical variability, and matrix interference. Coupling padlock-probe ligation, rolling circle amplification (RCA), and CRISPR–Cas12a offers sequence-selective recognition, isothermal amplification, and programmable readout. However, overall assay reliability depends on faithful molecular information transfer across the ligation, RCA, and Cas12a-activation interfaces rather than on the sensitivity of individual modules. This narrative review adopts an interface-centered framework to examine ligation-junction selectivity, RCA-product design, direct and secondary Cas12a-activation strategies, and mechanisms of background generation. We critically assess applications involving circulating tumor DNA mutations, circulating microRNAs, extracellular-vesicle-associated analytes, and cell-free DNA methylation, distinguishing integrated or related experimental implementations from component-level precedents and unvalidated extensions. Existing studies demonstrate analytical feasibility for selected targets, but quantitative reliability, scalable multiplexing, and clinical performance remain insufficiently established. We outline analytical validation requirements, including detection and quantification limits, specificity, matrix effects, reproducibility, contamination control, and concordance with orthogonal methods. Translation will require mechanistically traceable signal generation, robust performance in authentic specimens, prespecified thresholds, and validation in representative intended-use populations. Ultimately, progress should be judged by reproducible end-to-end performance and demonstrated contribution to clinical decisions, not by record-low detection limits in simplified systems.

Authors

Institutions

Publication Details

Journal
Egyptian Journal of Bronchology
Published
2026-11-23
DOI
https://doi.org/10.1186/s43168-026-00736-8
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Padlock probe–RCA–Cas12a for cancer liquid biopsy: molecular interface engineering, analytical validation, and clinical translation

Weixing Zhao, Jun Jiang, Xingru Ao, Siyu Li et al.
Egyptian Journal of Bronchology
Advanced biosensing and bioanalysis techniques
article

Padlock probe–RCA–Cas12a for cancer liquid biopsy: molecular interface engineering, analytical validation, and clinical translation

Weixing Zhao, Jun Jiang, Xingru Ao, Siyu Li, Jingjing Zhi
article en

Abstract

Liquid biopsy enables minimally invasive assessment of tumor-derived biomarkers, but reliable early cancer detection and longitudinal monitoring remain challenging because of low target abundance, background nucleic acids, preanalytical variability, and matrix interference. Coupling padlock-probe ligation, rolling circle amplification (RCA), and CRISPR–Cas12a offers sequence-selective recognition, isothermal amplification, and programmable readout. However, overall assay reliability depends on faithful molecular information transfer across the ligation, RCA, and Cas12a-activation interfaces rather than on the sensitivity of individual modules. This narrative review adopts an interface-centered framework to examine ligation-junction selectivity, RCA-product design, direct and secondary Cas12a-activation strategies, and mechanisms of background generation. We critically assess applications involving circulating tumor DNA mutations, circulating microRNAs, extracellular-vesicle-associated analytes, and cell-free DNA methylation, distinguishing integrated or related experimental implementations from component-level precedents and unvalidated extensions. Existing studies demonstrate analytical feasibility for selected targets, but quantitative reliability, scalable multiplexing, and clinical performance remain insufficiently established. We outline analytical validation requirements, including detection and quantification limits, specificity, matrix effects, reproducibility, contamination control, and concordance with orthogonal methods. Translation will require mechanistically traceable signal generation, robust performance in authentic specimens, prespecified thresholds, and validation in representative intended-use populations. Ultimately, progress should be judged by reproducible end-to-end performance and demonstrated contribution to clinical decisions, not by record-low detection limits in simplified systems.

Egyptian Journal of BronchologyVol. 20(1)
Qinghai University (CN), Qinghai University Affiliated Hospital (CN)
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon