Electrochemical characterization and degradation behavior of a commercial Ni–YSZ/YSZ/GDC/LSC single cell during high-temperature CO2 electrolysis

In the present work, the performance, electrochemical processes, and long-term stability of commercially available Ni–YSZ–based single cells (Ni–YSZ/YSZ/GDC/LSC) were investigated under high-temperature CO 2 electrolysis conditions. Electrochemical performance was evaluated using current–voltage (I–V) measurements and electrochemical impedance spectroscopy (EIS), while varying temperature, CO 2 concentration in the fuel gas, and oxygen partial pressure at the oxygen electrode. Maximum current densities of −1.77 A cm⁻ 2 at 900 °C and −1.34 A cm⁻ 2 at 800 °C were achieved at 1.5 V using a fuel gas composition of 80% CO 2 and 20% CO. Hysteresis behavior observed in the I–V curves were also analyzed. The impedance spectra were analyzed using distribution of relaxation times (DRT) and an equivalent circuit model, enabling the identification of fuel-electrode charge-transfer processes, oxide-ion transport through the electrolyte, oxygen-electrode processes, and gas diffusion processes. Stability test was investigated using separate commercial cells operated at 700, 750, and 800 °C for 814, 704, and 788 h, respectively. At −0.5 A cm −2 in nominal 80% CO 2 + 20% CO, the voltage-degradation rates were 25.59, 18.03, and 26.78 mV kh −1 , corresponding to normalized rates of 1.91, 1.44, and 2.45% kh −1 . Together with the high-current-density performance, hysteresis investigation, and EIS/DRT analysis, these results provide a temperature-resolved benchmark for commercial Ni–YSZ-based cells under CO 2 electrolysis conditions. Post-test SEM analysis revealed local morphological and interfacial differences in the Ni–YSZ fuel electrode, including localized pore-like features, while no substantial carbon deposition was observed under the tested conditions, demonstrating good stability during prolonged CO 2 electrolysis operation at high temperature.

Authors

Institutions

Publication Details

Journal
Journal of CO2 Utilization
Published
2026-11-23
DOI
https://doi.org/10.1016/j.jcou.2026.103629
Primary Topic
Advancements in Solid Oxide Fuel Cells
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Electrochemical characterization and degradation behavior of a commercial Ni–YSZ/YSZ/GDC/LSC single cell during high-temperature CO2 electrolysis

Vaibhav Vibhu, Vipin Kamboj, Rüdiger‐A. Eichel, Saranya Thankappakurup
Journal of CO2 Utilization
Advancements in Solid Oxide Fuel Cells
article

Electrochemical characterization and degradation behavior of a commercial Ni–YSZ/YSZ/GDC/LSC single cell during high-temperature CO2 electrolysis

Vaibhav Vibhu, Vipin Kamboj, Rüdiger‐A. Eichel, Saranya Thankappakurup
article en

Abstract

In the present work, the performance, electrochemical processes, and long-term stability of commercially available Ni–YSZ–based single cells (Ni–YSZ/YSZ/GDC/LSC) were investigated under high-temperature CO 2 electrolysis conditions. Electrochemical performance was evaluated using current–voltage (I–V) measurements and electrochemical impedance spectroscopy (EIS), while varying temperature, CO 2 concentration in the fuel gas, and oxygen partial pressure at the oxygen electrode. Maximum current densities of −1.77 A cm⁻ 2 at 900 °C and −1.34 A cm⁻ 2 at 800 °C were achieved at 1.5 V using a fuel gas composition of 80% CO 2 and 20% CO. Hysteresis behavior observed in the I–V curves were also analyzed. The impedance spectra were analyzed using distribution of relaxation times (DRT) and an equivalent circuit model, enabling the identification of fuel-electrode charge-transfer processes, oxide-ion transport through the electrolyte, oxygen-electrode processes, and gas diffusion processes. Stability test was investigated using separate commercial cells operated at 700, 750, and 800 °C for 814, 704, and 788 h, respectively. At −0.5 A cm −2 in nominal 80% CO 2 + 20% CO, the voltage-degradation rates were 25.59, 18.03, and 26.78 mV kh −1 , corresponding to normalized rates of 1.91, 1.44, and 2.45% kh −1 . Together with the high-current-density performance, hysteresis investigation, and EIS/DRT analysis, these results provide a temperature-resolved benchmark for commercial Ni–YSZ-based cells under CO 2 electrolysis conditions. Post-test SEM analysis revealed local morphological and interfacial differences in the Ni–YSZ fuel electrode, including localized pore-like features, while no substantial carbon deposition was observed under the tested conditions, demonstrating good stability during prolonged CO 2 electrolysis operation at high temperature.

Journal of CO2 UtilizationVol. 114
Forschungszentrum Jülich (DE), RWTH Aachen University (DE)
Bundesministerium für Forschung, Technologie und Raumfahrt
Advancements in Solid Oxide Fuel Cells
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon