Measurement Chain Artefacts and Faraday Shielding in Electrochemical Impedance Spectroscopy

Electrochemical impedance spectroscopy (EIS) is susceptible to contributions from instrumentation, fixtures, grounding, shielding, and electromagnetic disturbances. This study examined enclosure and transformer-state sensitivity across two campaigns comprising 388 passive dummy-circuit spectra and 104 Samsung INR18650-25R cell spectra. Assessment combined relative complex-impedance deviations, replicate-based Type-A uncertainty, instrument accuracy-contour screening, and fixed-order, 24-RC KK-compatible residual analysis. With an energized but unloaded transformer, Campaign A dummy measurements yielded maximum deviations of 22.30% at 100 µV, 2.05% at 1 mV, and 0.274% at 10 mV, with the strongest response near 49.867 Hz. Campaign B reproduced the amplitude-dependent pattern across four repetitions per transformer state, but corresponding maxima were reduced to 5.31%, 0.460%, and 0.112%, demonstrating variable rather than fixed interference magnitude. Galvanostatic dummy deviations remained comparatively small. For the cell, plain-table transformer-state deviations were 0.163% at 49.867 Hz in Campaign A and 0.061–0.249% across Campaign B excitation settings; none of the Campaign B values exceeded the Type-A repeatability-based detection threshold. Campaign B maxima reached 2.01–2.19% at 79.5–100 kHz, where instrument and fixture contributions limit interpretation. Enclosure comparisons identified no consistently superior configuration under these conditions, while sequential cell-voltage evolution limited causal attribution. Thus, disturbance detectability depends on the complete measurement chain, and dummy-circuit findings cannot be quantitatively transferred to cylindrical-cell EIS.

Authors

Institutions

Publication Details

Journal
Batteries
Published
2026-11-23
DOI
https://doi.org/10.3390/batteries12120505
Primary Topic
Battery Modeling and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Measurement Chain Artefacts and Faraday Shielding in Electrochemical Impedance Spectroscopy

Krisztián Enisz, Péter Gulyás, Szabolcs Kocsis Szürke
Batteries
Battery Modeling and Management
article

Measurement Chain Artefacts and Faraday Shielding in Electrochemical Impedance Spectroscopy

Krisztián Enisz, Péter Gulyás, Szabolcs Kocsis Szürke
article en

Abstract

Electrochemical impedance spectroscopy (EIS) is susceptible to contributions from instrumentation, fixtures, grounding, shielding, and electromagnetic disturbances. This study examined enclosure and transformer-state sensitivity across two campaigns comprising 388 passive dummy-circuit spectra and 104 Samsung INR18650-25R cell spectra. Assessment combined relative complex-impedance deviations, replicate-based Type-A uncertainty, instrument accuracy-contour screening, and fixed-order, 24-RC KK-compatible residual analysis. With an energized but unloaded transformer, Campaign A dummy measurements yielded maximum deviations of 22.30% at 100 µV, 2.05% at 1 mV, and 0.274% at 10 mV, with the strongest response near 49.867 Hz. Campaign B reproduced the amplitude-dependent pattern across four repetitions per transformer state, but corresponding maxima were reduced to 5.31%, 0.460%, and 0.112%, demonstrating variable rather than fixed interference magnitude. Galvanostatic dummy deviations remained comparatively small. For the cell, plain-table transformer-state deviations were 0.163% at 49.867 Hz in Campaign A and 0.061–0.249% across Campaign B excitation settings; none of the Campaign B values exceeded the Type-A repeatability-based detection threshold. Campaign B maxima reached 2.01–2.19% at 79.5–100 kHz, where instrument and fixture contributions limit interpretation. Enclosure comparisons identified no consistently superior configuration under these conditions, while sequential cell-voltage evolution limited causal attribution. Thus, disturbance detectability depends on the complete measurement chain, and dummy-circuit findings cannot be quantitatively transferred to cylindrical-cell EIS.

BatteriesVol. 12(12)
Széchenyi István University (HU)
Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
Battery Modeling and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Measurement Chain Artefacts and Faraday Shielding in Electrochemical Impedance Spectroscopy — Krisztián Enisz, Péter Gulyás, et al. · Batteries (2026) | TGRS Research Map | TGRS