Reflective Fiber-Tip Silica Microsphere Interferometer for Temperature Monitoring in Ethylene Glycol

We experimentally investigate a reflective fiber-tip interferometric sensor comprising a fused-silica microsphere at the end of a single-mode fiber and an external mirror, both immersed in ethylene glycol. The sensor was interrogated with a broadband source, an optical circulator, and an optical spectrum analyzer. For the five retained heating spectra, the selected peak shifted from 1546.35 nm at 25.2 °C to 1548.53 nm at 65.2 °C. The fitted wavelength slope was 51.6 pm/°C (R2 = 0.9862). Ten consecutive spectral acquisitions at 40.5 °C showed a standard deviation of 0.163 nm in the tracked peak position. The positive shift is inconsistent with a fixed-gap response governed solely by the negative thermo-optic coefficient of ethylene glycol. The individual contributions to the shift were not isolated. These measurements establish the feasibility of the proposed single-ended architecture for temperature monitoring in ethylene glycol, while highlighting the need for improved thermal referencing, mechanical stabilization, and repeated heating–cooling cycles before quantitative metrological claims can be made.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2026-11-23
DOI
https://doi.org/10.3390/eng7120664
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reflective Fiber-Tip Silica Microsphere Interferometer for Temperature Monitoring in Ethylene Glycol

A. Castillo-Guzmán, Yamil Alejandro Zúñiga-Ávalos, René Fernando Domínguez-Cruz, Romeo J. Selvas-Aguilar et al.
Eng—Advances in Engineering
Advanced Fiber Optic Sensors
article

Reflective Fiber-Tip Silica Microsphere Interferometer for Temperature Monitoring in Ethylene Glycol

A. Castillo-Guzmán, Yamil Alejandro Zúñiga-Ávalos, René Fernando Domínguez-Cruz, Romeo J. Selvas-Aguilar, Yadira Aracely Fuentes-Rubio, Susan Ximena Mendoza-Trejo
article en

Abstract

We experimentally investigate a reflective fiber-tip interferometric sensor comprising a fused-silica microsphere at the end of a single-mode fiber and an external mirror, both immersed in ethylene glycol. The sensor was interrogated with a broadband source, an optical circulator, and an optical spectrum analyzer. For the five retained heating spectra, the selected peak shifted from 1546.35 nm at 25.2 °C to 1548.53 nm at 65.2 °C. The fitted wavelength slope was 51.6 pm/°C (R2 = 0.9862). Ten consecutive spectral acquisitions at 40.5 °C showed a standard deviation of 0.163 nm in the tracked peak position. The positive shift is inconsistent with a fixed-gap response governed solely by the negative thermo-optic coefficient of ethylene glycol. The individual contributions to the shift were not isolated. These measurements establish the feasibility of the proposed single-ended architecture for temperature monitoring in ethylene glycol, while highlighting the need for improved thermal referencing, mechanical stabilization, and repeated heating–cooling cycles before quantitative metrological claims can be made.

Eng—Advances in EngineeringVol. 7(12)
Universidad Autónoma de Nuevo León (MX), Autonomous University of Tamaulipas (MX)
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.