Track Coverage and Numerical Tolerances in Simulated Depressed-Cladding Silica Waveguides

Laser-written index tracks around an unmodified silica core approximate a continuous depressed cladding. We quantify that approximation with a scalar split-step solver and a partial-area detector. In a 13-case numerical study at 1,550 nm, the continuous ring retained 36.18% of incident power in the core after 2 mm. Unscaled profiles with 48, 96 and 192 tracks retained 14.29%, 33.11% and 35.49%, respectively. Omitting eight of 96 track centers reduced the fraction to 21.39%. The 96-track profile matched in integrated index contrast reached 36.60%. Grid refinements and cross-solver comparisons passed their scalar endpoint checks, while a separate track-convergence test remained unresolved. In a complementary four-port coupled-mode model, increasing phase noise from 0.05 to 0.10 rad raised the 95th percentile of the relative intensity error from 9.5% to 18.6%. These are recorded numerical results for two building blocks of guided-wave optical computing. The same manuscript appears on the author's Academia.edu profile: https://www.academia.edu/181672688/Track_Coverage_and_Numerical_Tolerances_in_Simulated_Depressed_Cladding_Silica_Waveguides

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-23
DOI
https://doi.org/10.5281/zenodo.24467135
Primary Topic
Photonic and Optical Devices
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Track Coverage and Numerical Tolerances in Simulated Depressed-Cladding Silica Waveguides

Francisco Angulo De Lafuente
Zenodo (CERN European Organization for Nuclear Research)
Photonic and Optical Devices
preprint

Track Coverage and Numerical Tolerances in Simulated Depressed-Cladding Silica Waveguides

Francisco Angulo De Lafuente
preprint en

Abstract

Laser-written index tracks around an unmodified silica core approximate a continuous depressed cladding. We quantify that approximation with a scalar split-step solver and a partial-area detector. In a 13-case numerical study at 1,550 nm, the continuous ring retained 36.18% of incident power in the core after 2 mm. Unscaled profiles with 48, 96 and 192 tracks retained 14.29%, 33.11% and 35.49%, respectively. Omitting eight of 96 track centers reduced the fraction to 21.39%. The 96-track profile matched in integrated index contrast reached 36.60%. Grid refinements and cross-solver comparisons passed their scalar endpoint checks, while a separate track-convergence test remained unresolved. In a complementary four-port coupled-mode model, increasing phase noise from 0.05 to 0.10 rad raised the 95th percentile of the relative intensity error from 9.5% to 18.6%. These are recorded numerical results for two building blocks of guided-wave optical computing. The same manuscript appears on the author's Academia.edu profile: https://www.academia.edu/181672688/Track_Coverage_and_Numerical_Tolerances_in_Simulated_Depressed_Cladding_Silica_Waveguides

Zenodo (CERN European Organization for Nuclear Research)
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Track Coverage and Numerical Tolerances in Simulated Depressed-Cladding Silica Waveguides — Francisco Angulo De Lafuente · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS