Resorption of the greater tuberosity after translesional fixation with blocked threaded wires of complex humeral head fractures

Background Despite advances with the last generation of locking plate fixation, postoperative greater tuberosity (GT) malunion or resorption, in case of complex humeral head fractures, is frequently reported and associated with unsatisfactory functional outcomes. The incidence and determinants of GT resorption appear to be influenced by both biological and mechanical factors and may vary according to the fixation system used. Evidence regarding GT healing following translesional fixation technique remains limited. Materials and methods A retrospective cohort study was conducted on 179 patients with three-part proximal humerus fractures treated with translesional fixation using a standardized configuration of blocked threaded wires between January 2016 and December 2023. Patients were divided into two groups according to age: ≤ 70 and more than 70 years. All procedures were performed using a standardized surgical technique, followed by the same postoperative rehabilitation protocol. Radiographic evaluation was performed at 1, 3, 6, and 12 months postoperatively using standard anteroposterior and axillary views. Three independent, blinded examiners assessed GT consolidation. Interobserver reliability was calculated. Results At the final 12-month follow-up, GT healing was observed in 98.7% of patients aged ≤ 70 years and in 100% of patients aged ≥ 71 years; slight GT malunion with radiographic healing was detected in 8.9% and 10.9% of the two groups, respectively. Only one case of GT resorption was identified as a consequence of a postoperative deep infection. Interobserver agreement for radiographic assessment was perfect in all cases ( κ = 1.00). Conclusions Translesional fixation, consisting of a standardized construct of blocked threaded wires, provides excellent greater tuberosity healing rates in three-part proximal humeral fractures, with a negligible incidence of tuberosity resorption regardless of patient age. Based on these considerations, it can be inferred that GT resorption is strongly influenced by the fixation system employed. Level of evidence: III.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedics and Traumatology
Published
2026-11-23
DOI
https://doi.org/10.1186/s10195-026-00984-w
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Resorption of the greater tuberosity after translesional fixation with blocked threaded wires of complex humeral head fractures

Vittorio Candela, Alessandro Calistri, Gumina Stefano, F. Colangelo et al.
Journal of Orthopaedics and Traumatology
Shoulder Injury and Treatment
article

Resorption of the greater tuberosity after translesional fixation with blocked threaded wires of complex humeral head fractures

Vittorio Candela, Alessandro Calistri, Gumina Stefano, F. Colangelo, A. Gallo, D. Bartocci
article en

Abstract

Background Despite advances with the last generation of locking plate fixation, postoperative greater tuberosity (GT) malunion or resorption, in case of complex humeral head fractures, is frequently reported and associated with unsatisfactory functional outcomes. The incidence and determinants of GT resorption appear to be influenced by both biological and mechanical factors and may vary according to the fixation system used. Evidence regarding GT healing following translesional fixation technique remains limited. Materials and methods A retrospective cohort study was conducted on 179 patients with three-part proximal humerus fractures treated with translesional fixation using a standardized configuration of blocked threaded wires between January 2016 and December 2023. Patients were divided into two groups according to age: ≤ 70 and more than 70 years. All procedures were performed using a standardized surgical technique, followed by the same postoperative rehabilitation protocol. Radiographic evaluation was performed at 1, 3, 6, and 12 months postoperatively using standard anteroposterior and axillary views. Three independent, blinded examiners assessed GT consolidation. Interobserver reliability was calculated. Results At the final 12-month follow-up, GT healing was observed in 98.7% of patients aged ≤ 70 years and in 100% of patients aged ≥ 71 years; slight GT malunion with radiographic healing was detected in 8.9% and 10.9% of the two groups, respectively. Only one case of GT resorption was identified as a consequence of a postoperative deep infection. Interobserver agreement for radiographic assessment was perfect in all cases ( κ = 1.00). Conclusions Translesional fixation, consisting of a standardized construct of blocked threaded wires, provides excellent greater tuberosity healing rates in three-part proximal humeral fractures, with a negligible incidence of tuberosity resorption regardless of patient age. Based on these considerations, it can be inferred that GT resorption is strongly influenced by the fixation system employed. Level of evidence: III.

Journal of Orthopaedics and Traumatology
Sapienza University of Rome (IT)
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon