Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysis

Background/objectives Minimizing radiation-induced late effects is critical in pediatric neuro-oncology, where long life expectancy is associated with treatment-related toxicity. We evaluated the 15-year institutional transition from three-dimensional conformal radiotherapy (3D-CRT) to volumetric modulated arc therapy (VMAT) and compared their dosimetric performance in pediatric focal brain radiotherapy (FBRT). Methods Between 2011 and 2025, 27,393 patients were treated, including 175 pediatric cases (≤18 years). FBRT cases were selected for dosimetric analysis because they are the most common pediatric brain irradiation at our institution and involve small-to-medium targets located near radiosensitive critical structures, enabling a sensitive comparison of technique-dependent dosimetric differences. FBRT plans from 27 patients were analyzed (3D-CRT: n = 13; VMAT: n = 14) using a unified script-based workflow in RayStation combined with a standardized AI-based auto-segmentation tool. Metrics included V95%, homogeneity index (HI), conformity index (CI), and high-dose spillage (V102%). Exploratory organ at risk (OAR) analysis was performed in a more restricted prescription uniform subgroup. In addition, overall survival (OS) was evaluated using available clinical follow-up data from FBRT patients. Results VMAT significantly reduced high-dose volumes (V102%: 0.01% vs. 0.78%, p = 3.8 × 10 −4 ), improved conformity (CI: 0.85 vs. 0.64, p = 0.008) and homogeneity (HI: 1.07 vs. 1.10, p = 0.048) compared with 3D-CRT. Target coverage was comparable. OAR analysis showed consistently reduced maximum doses to the optic chiasm and pituitary gland. No statistically significant difference in overall survival was observed between treatment techniques (p = 0.26). Conclusion Overall, our study demonstrates that the application of VMAT in pediatric focal brain irradiation improves the precision of dose distribution and may contribute to reducing long-term neurocognitive and endocrine toxicities. These findings support the clinical use of VMAT, with the potential to reduce late treatment-related toxicity in the pediatric patient population.

Authors

Institutions

Publication Details

Journal
Pathology & Oncology Research
Published
2026-11-23
DOI
https://doi.org/10.3389/pore.2026.1612501
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysis

Judit Papp, Gábor Mocsár, Mihály Simon, István Szegedi et al.
Pathology & Oncology Research
Advanced Radiotherapy Techniques
article

Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysis

Judit Papp, Gábor Mocsár, Mihály Simon, István Szegedi, Csongor Kiss, Kristóf Gál, Lilla Macsi, Árpád Kovács, Dóra Kovács-Solymosi
article en

Abstract

Background/objectives Minimizing radiation-induced late effects is critical in pediatric neuro-oncology, where long life expectancy is associated with treatment-related toxicity. We evaluated the 15-year institutional transition from three-dimensional conformal radiotherapy (3D-CRT) to volumetric modulated arc therapy (VMAT) and compared their dosimetric performance in pediatric focal brain radiotherapy (FBRT). Methods Between 2011 and 2025, 27,393 patients were treated, including 175 pediatric cases (≤18 years). FBRT cases were selected for dosimetric analysis because they are the most common pediatric brain irradiation at our institution and involve small-to-medium targets located near radiosensitive critical structures, enabling a sensitive comparison of technique-dependent dosimetric differences. FBRT plans from 27 patients were analyzed (3D-CRT: n = 13; VMAT: n = 14) using a unified script-based workflow in RayStation combined with a standardized AI-based auto-segmentation tool. Metrics included V95%, homogeneity index (HI), conformity index (CI), and high-dose spillage (V102%). Exploratory organ at risk (OAR) analysis was performed in a more restricted prescription uniform subgroup. In addition, overall survival (OS) was evaluated using available clinical follow-up data from FBRT patients. Results VMAT significantly reduced high-dose volumes (V102%: 0.01% vs. 0.78%, p = 3.8 × 10 −4 ), improved conformity (CI: 0.85 vs. 0.64, p = 0.008) and homogeneity (HI: 1.07 vs. 1.10, p = 0.048) compared with 3D-CRT. Target coverage was comparable. OAR analysis showed consistently reduced maximum doses to the optic chiasm and pituitary gland. No statistically significant difference in overall survival was observed between treatment techniques (p = 0.26). Conclusion Overall, our study demonstrates that the application of VMAT in pediatric focal brain irradiation improves the precision of dose distribution and may contribute to reducing long-term neurocognitive and endocrine toxicities. These findings support the clinical use of VMAT, with the potential to reduce late treatment-related toxicity in the pediatric patient population.

Pathology & Oncology ResearchVol. 32
University of Debrecen (HU)
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon