TinyML Benchmarking for Embedded sEMG Gesture Classification: Quantized Model Design and an Accessible Robotic Hand Prosthesis Demonstration
Surface electromyography (sEMG) enables non-invasive prosthetic control, but deployment is limited by non-stationary signals, noise and embedded-computing constraints. This work presents a mathematically defined pipeline for real-time control of an accessible, commodity-component robotic hand prosthesis (no formal bill-of-materials or aggregate cost figure is claimed) from eight-channel Myo Armband sEMG, together with a deployment-oriented benchmarking study of quantized TinyML classifiers, benchmarked independently of the physical prosthesis rather than executed on it. The sEMG stream is filtered, windowed and classified by a hybrid CNN-BiLSTM reference model, converting posterior probabilities into PWM prosthetic commands on a Raspberry Pi. Five gesture classes were considered, using data from a single able-bodied participant, framed as a within-subject feasibility study. From 167,712 labeled samples, the reference model reached 99.6% test accuracy (99.58% macro F1) on a session-disjoint split. Because this reference model targets a Raspberry Pi rather than a microcontroller, four quantized TinyML candidates (TCN ensemble, embedded-C Random Forest, MLP ensemble, decision tree) were additionally designed and benchmarked under a common accuracy-footprint-inference-time protocol. Quantization cost was substantial: the deployed int8 TCN reached 83.5% smoothed accuracy versus 90.1% float32, while an embedded-C Random Forest reached 90.7% at only 17.9 KB. SHAP analysis revealed model-dependent channel importance patterns, with the TCN ensemble and the Random Forest ranking electrode channels differently because they exploit different signal representations. Embedded operation and a qualitative functional demonstration on the physical prosthesis, assessed by visual observation rather than instrumented kinematics, grasp force or task-success measurements, confirmed feasibility, while cross-subject validation, direct on-device latency measurements and component-wise ablation remain necessary before clinical or daily-use claims.
Authors
- César Hernando Valencia Niño (ORCID: https://orcid.org/0000-0001-6077-6458)
- Alvarez Ronald (ORCID: https://orcid.org/0009-0004-9842-3323)
- Lopez Juan Jose (ORCID: https://orcid.org/0009-0006-3742-9187)
- Barrera Yennzy (ORCID: https://orcid.org/0009-0007-4214-7819)
- Gutierrez Cristhiam (ORCID: https://orcid.org/0009-0003-5634-8778)
Institutions
- Unidades Tecnológicas de Santander (CO)
Publication Details
- Journal
- Technologies
- Published
- 2026-11-23
- DOI
- https://doi.org/10.3390/technologies14120780
- Primary Topic
- Muscle activation and electromyography studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00