Comparison of mold-based, handmade, and prefabricated articulating cement spacers in two-stage revision total knee arthroplasty for periprosthetic joint infection: a retrospective comparative study
Introduction Periprosthetic joint infection (PJI) following total knee arthroplasty (TKA) is a devastating complication most commonly managed with two-stage revision. Articulating antibiotic-loaded cement spacers may be prepared using handmade, mold-based, or prefabricated techniques; however, high-quality comparative evidence is limited, and the 2025 International Consensus Meeting on Musculoskeletal Infection identified this as a knowledge gap. We aimed to compare a mold-based technique that uses a dedicated reusable sterile mold prepared from previously explanted components, used solely as a back-table molding tool and never reimplanted into the joint, with conventional handmade and commercially available prefabricated spacers. Materials and methods We retrospectively analyzed 75 patients undergoing two-stage revision TKA for PJI (June 2019–August 2025), grouped by spacer technique: mold-based ( n = 18), handmade ( n = 36), and prefabricated ( n = 21). PJI was diagnosed per the 2018 ICM criteria. The primary outcome was final range of motion (ROM). Secondary outcomes were KSS, WOMAC, Oxford Knee Score, infection eradication, complications, and per-patient cost. Groups were compared using Kruskal–Wallis and chi-square/Fisher tests with Bonferroni post-hoc correction. Results Baseline demographics and infection markers were comparable across groups. Final ROM tended to be highest in the mold group (105.8° ± 13.6°) compared with the handmade (99.3° ± 11.7°) and prefabricated (103.1° ± 11.1°) groups, without reaching statistical significance ( p = 0.227). No significant differences were observed in KSS-Knee, KSS-Function, WOMAC, or Oxford scores. Infection eradication rates were 94.4% (mold), 94.4% (handmade), and 90.5% (prefabricated) ( p = 0.826). Spacer-related complications occurred in 11.1%, 30.6%, and 14.3%, respectively ( p = 0.168), with all spacer fractures ( n = 4) confined to the handmade group. In our institutional setting, the direct material cost of the mold-based construct was approximately 46% of the prefabricated spacer construct cost (approximately 54% lower). Conclusions The mold-based technique using explanted components yielded clinical outcomes that did not differ significantly from those of handmade and prefabricated spacers, with a lower direct material cost than the prefabricated spacer, and may represent a practical lower-cost alternative to prefabricated spacers in resource-limited settings. Larger prospective studies are needed to confirm these findings. Level of evidence III—retrospective comparative study.
Authors
- Olgun Bingöl (ORCID: https://orcid.org/0000-0003-1720-1709)
- Bülent Özkurt (ORCID: https://orcid.org/0000-0002-6135-1870)
- Özdamar Fuad Öken (ORCID: https://orcid.org/0000-0002-3091-9697)
- Yakup Kahve (ORCID: https://orcid.org/0000-0003-2317-0830)
- Tahsin Aydın (ORCID: https://orcid.org/0000-0001-5142-5605)
- Erman Ceyhan (ORCID: https://orcid.org/0000-0002-8095-6058)
Institutions
- Ankara Bilkent City Hospital (TR)
Publication Details
- Journal
- Archives of Orthopaedic and Trauma Surgery
- Published
- 2026-11-23
- DOI
- https://doi.org/10.1007/s00402-026-06574-z
- Primary Topic
- Orthopedic Infections and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00