Multi-Pass Focused Helium Ion Beam Processing for Reducing Ga-FIB-Induced Surface Damage in Single-Crystal Diamond

Single-crystal diamond has attracted considerable attention for applications in quantum information processing, nanophotonics, and microelectromechanical systems. However, focused gallium ion beam (Ga-FIB) milling introduces near-surface structural damage and gallium implantation, which may adversely affect the performance of diamond-based nanostructures. In this study, focused helium ion beam (He-HIM) post-processing was investigated as a potential approach for reducing Ga-FIB-induced surface damage in single-crystal diamond. The effects of helium ion dose, beam current, and multi-pass processing conditions on the damaged-layer thickness were systematically examined using cross-sectional transmission electron microscopy (TEM), high-resolution TEM (HRTEM), energy-dispersive X-ray spectroscopy (EDS), and selected-area electron diffraction (SAED). The results showed that helium ion irradiation at a dose of 5 × 10¹⁵ ions/cm² reduced the local damaged-layer thickness from 200.39 ± 1.46 nm to 192.97 ± 1.06 nm, whereas higher doses resulted in increased damaged-layer thickness. Beam-current experiments revealed that regions processed at 13–29.67 pA exhibited thicker damaged layers than the 12 pA reference regions, although no monotonic dependence on beam current was observed. Based on these findings, two six-pass He-HIM processing strategies were implemented using progressively reduced beam currents or ion doses. Compared with corresponding Ga-FIB-only reference regions, the multi-pass treatments reduced the local damaged-layer thickness by approximately 5.6% and 8.0%, respectively. These findings suggest that carefully controlled He-HIM post-processing can moderately reduce Ga-FIB-induced surface damage, while excessive irradiation may introduce additional structural defects. This study provides experimental guidance for optimizing helium ion beam post-processing of diamond nanostructures.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-23
DOI
https://doi.org/10.21203/rs.3.rs-11426116/v1
Primary Topic
Ion-surface interactions and analysis
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Multi-Pass Focused Helium Ion Beam Processing for Reducing Ga-FIB-Induced Surface Damage in Single-Crystal Diamond

王成勇, Fengling Zou, Zhishan Yuan, Zelong Lin et al.
Research Square
Ion-surface interactions and analysis
preprint

Multi-Pass Focused Helium Ion Beam Processing for Reducing Ga-FIB-Induced Surface Damage in Single-Crystal Diamond

王成勇, Fengling Zou, Zhishan Yuan, Zelong Lin, Yun Zheng, Yisen Chen, Lijuan Zheng
preprint en

Abstract

Single-crystal diamond has attracted considerable attention for applications in quantum information processing, nanophotonics, and microelectromechanical systems. However, focused gallium ion beam (Ga-FIB) milling introduces near-surface structural damage and gallium implantation, which may adversely affect the performance of diamond-based nanostructures. In this study, focused helium ion beam (He-HIM) post-processing was investigated as a potential approach for reducing Ga-FIB-induced surface damage in single-crystal diamond. The effects of helium ion dose, beam current, and multi-pass processing conditions on the damaged-layer thickness were systematically examined using cross-sectional transmission electron microscopy (TEM), high-resolution TEM (HRTEM), energy-dispersive X-ray spectroscopy (EDS), and selected-area electron diffraction (SAED). The results showed that helium ion irradiation at a dose of 5 × 10¹⁵ ions/cm² reduced the local damaged-layer thickness from 200.39 ± 1.46 nm to 192.97 ± 1.06 nm, whereas higher doses resulted in increased damaged-layer thickness. Beam-current experiments revealed that regions processed at 13–29.67 pA exhibited thicker damaged layers than the 12 pA reference regions, although no monotonic dependence on beam current was observed. Based on these findings, two six-pass He-HIM processing strategies were implemented using progressively reduced beam currents or ion doses. Compared with corresponding Ga-FIB-only reference regions, the multi-pass treatments reduced the local damaged-layer thickness by approximately 5.6% and 8.0%, respectively. These findings suggest that carefully controlled He-HIM post-processing can moderately reduce Ga-FIB-induced surface damage, while excessive irradiation may introduce additional structural defects. This study provides experimental guidance for optimizing helium ion beam post-processing of diamond nanostructures.

Research Square
Guangdong University of Technology (CN)
National Natural Science Foundation of China
Ion-surface interactions and analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Multi-Pass Focused Helium Ion Beam Processing for Reducing Ga-FIB-Induced Surface Damage in Single-Crystal Diamond — 王成勇, Fengling Zou, et al. · Research Square (2026) | TGRS Research Map | TGRS